Reference
Only
Manitowoc
Published 12-05-17, Control # 035-23
7-5
18000 SERIVCE/MAINTENANCE MANUAL
POWER TRAIN
7
•
OFF when DPF is full and Red Engine Stop Light is ON.
The soot level is critically high and past the point of a
manual stationary regeneration. The operator will notice
a significant reduction in engine power.
Turn off
regeneration inhibit switch and shut down crane.
Do
NOT
perform a manual stationary regeneration. The
DPF must be removed from the crane and physically
cleaned and the Red Engine Warning Light can only be
cleared by a Cummins Service Technician, see Engine
Manufacturer’s Manual for details.
DPF Regeneration Inhibit On
GLOWS YELLOW when active regeneration has been
stopped by pressing the Inhibit function (bottom) of the
regeneration switch. Excessive use of regeneration inhibit
will result in the need to service or replace the DPF.
DPF Regeneration/Inhibit Switch
The DPF switch is a three position switch. Top position is
momentary. Center and bottom position are maintained.
CENTER position is for NORMAL engine operation.
Regeneration of the DPF will occur automatically.
Press TOP of rocker to START manual stationary
regeneration. Release switch back to center position.
Cummins ECM will control a DPF regeneration if necessary.
It is normal for the DPF High Temperature lamp to illuminate.
Perform a manual stationary regeneration
only
if indicated
by the DPF diagnostic in the Tier 4 Engine Diagnostics —
Cummins QSX15 Tier 4, (see
for details).
NOTE:
A guard over the top of the rocker prevents
accidental manual regeneration of the DPF.
Press BOTTOM of rocker to INHIBIT active regeneration.
The amber LED in the rocker will glow.
Use INHIBIT only for special circumstances where it is
desirable to disable active regeneration. Prolonged engine
operation with INHIBIT on will cause the DPF to fill with soot.
Too much soot could cause the engine to stop. If that occurs
it will be necessary to clean the DPF before the engine can
be restarted.
See Engine Manufacturer’s Manual for additional information
regarding stationary regeneration and DPF inhibit operating
instructions.
DPF Diagnostics
Item
Description
1
DPF Regeneration/Inhibit Switch
2
Right Hand Console Accessory Panel
3
Engine Maintenance Light — White
4
Engine Warning Light — Amber
5
Engine Stop Light — Red
6
DPF Inhibit On — Amber
7
DPF Regeneration On — Amber
8
DPF High Temperature — Amber
9
Front Console (Tier 4)
5
8 7 6
4 3
FIGURE 7-5
1
2
9
A06374_b
A06374
Summary of Contents for 18000
Page 1: ...R e f e r e n c e O n l y Service Maintenance Manual Manitowoc 18000 ...
Page 2: ...R e f e r e n c e O n l y ...
Page 4: ...R e f e r e n c e O n l y THE ORIGINAL LANGUAGE OF THIS PUBLICATION IS ENGLISH ...
Page 210: ...R e f e r e n c e O n l y NOTES SKETCHES AND PHOTOGRAPHS ...
Page 315: ...R e f e r e n c e O n l y ...
Page 316: ...R e f e r e n c e O n l y ...