76-b
AI-10
Swing Right Pressure Sender
1 Volt at 0 psi;
5 Volts at 7,500 psi
CAN18-4
1
76-c
AI-11
Swing Brake Pressure Sender
1 Volt at 0 psi;
5 Volts at 750 psi
CAN18-6
1
76-j
Ground
Swing Motor Speed Sensor
Ground
76-n
ENC-1A
Swing Motor Speed Sensor CH A
1.2 or 3.2 Volts Not Moving;
2.2 Volts Moving
CAN64-2
2
76-p
ENC-1B
Swing Motor Speed Sensor CH B
1.2 or 3.2 Volts Not Moving;
2.2 Volts Moving
CAN64-2
2
1
– Lower four bits are the most significant bit of the analog value.
2
– The number in the indicated bank should increase with device rotation and decrease with rotation in opposite direction.
Can ID. No.
Function
Type
Description
Test Voltages
Packet No.