Reference
Only
ELECTRIC SYSTEM
18000 SERIVCE/MAINTENANCE MANUAL
3-24
Published 12-05-17, Control # 035-23
NODE 9 - MAX-ER
Reference Electrical Schematic A06374 - Sheets 13, 19 and 21
.
Can ID. #
/Connector #
Function
Type
Description
Test Voltage
Packet No.
WN14-A/WN14-A
24 Volts
From Node 5 to Remote Receiver
24 Volts Nominal
WN14-C/WN14-C
CANH
Can High Wire Transmission
N/A
WN14-D/WN14-D
Ground
From Node 5 to Remote Receiver
Ground
WN14-F/WN14-F
CANL
Can Low Wire Transmission
N/A
J3
Receptacle – MAX-ER Controls
93-A
Ground
MAX-ER Right Side CWT Carrier Load PIn Ground
93-B
24 Volts
W48 Shorting Plug (MAX-ER not used)
24 Volts Nominal
93-D
DO-2
CWT Left Cylinder - Retract Solenoid
0 Volts Off, 24 Volts On
CAN37-1-2
93-F
DO-3
Counterweight Limit Switch
0 Volts Off, 24 Volts On
CAN37-1-4
93-H
DO-4
CWT Right Cylinder - Retract Solenoid
0 Volts Off, 24 Volts On
CAN37-1-8
93-J
Ground
Jumper to Node Select 2
Ground
93-L
NS-2
Node Select 2 Jumper to Ground
0 Volts (With Jumper)
93-M
NS-3
Node Select 3 Jumper to Ground
0 Volts (With Jumper)
93-N
Ground
Jumper to Node Select 3
Ground
93-P
DO-6
CWT Right Cylinder - Extend Solenoid
0 Volts Off, 24 Volts On
CAN37-1-32
93-R
DO-5
CWT Left Cylinder - Extend Solenoid
0 Volts Off, 24 Volts On
CAN37-1-16
93-T
DI-3
Counterweight Limit Switch - Right Side
0 Volts Off, 24 Volts On
CAN67-1-4
93-W
DI-4
Counterweight Limit Switch - Left Side
0 Volts Off, 24 Volts On
CAN67-1-8
93-X
24 Volts
MAX-ER Right Side CWT Carrier Load PIn 24 Volts
93-Z
24 Volts
MAX-ER Left Side CWT Carrier Load PIn
24 Volts
93-a
AI-1
Remote Active
24 Volts Nominal
CAN20-2-16
93-b
AI-2
CWT Pendant Cylinder Remote-Lower
0 Volts Off, 24 Volts On
CAN20-2-32
93-c
AI-3
CWT Pendant Cylinder Remote-Raise
0 Volts Off, 24 Volts On
CAN20-6
1
93-d
AI-4
MAX-ER Right Side CWT Carrier Load PIn 0.8 Volts Min.; 8.0 Volts Max. CAN20-8
1
93-e
AI-5
MAX-ER Left Side CWT Carrier Load PIn
0.8 Volts Min.;8.0 Volts Max. CAN21-2
1
93-g
Ground
MAX-ER Left Side CWT Carrier Load PIn
Ground
93-h
Ground
Counterweight Limit Switch Ground
Ground
93-k
Ground
Counterweight Limit Switch Ground
Ground
93-m
Ground
MAX-ER Backhitch Load Pin
Ground
93-p
AI-7
W48 Shorting Plug (MAX-ER not used)
0 Volts Off, 24 Volts On
CAN21-2-64
93-r
AI-8
MAX-ER Backhitch Load Pin
No Load 1.5 Volts
CAN21-8
1
93-s
24 Volts
MAX-ER Backhitch Load PIn
24 Volts
J6
Receptacle – MAX-ER Controls
96B
DO-7
Power to MAX-ER Remote Control
0 Volts Off, 24 Volts On
CAN37-1-64
96D
DO-8
Power to MAX-ER Remote Control
0 Volts Off, 24 Volts On
CAN37-1-128
96F
DO-9
Power to MAX-ER Remote Control
0 Volts Off, 24 Volts On
CAN37-2-1
96H
DO-10
Power to MAX-ER Remote Control
0 Volts Off, 24 Volts On
CAN37-2-2
Summary of Contents for 18000
Page 1: ...R e f e r e n c e O n l y Service Maintenance Manual Manitowoc 18000 ...
Page 2: ...R e f e r e n c e O n l y ...
Page 4: ...R e f e r e n c e O n l y THE ORIGINAL LANGUAGE OF THIS PUBLICATION IS ENGLISH ...
Page 210: ...R e f e r e n c e O n l y NOTES SKETCHES AND PHOTOGRAPHS ...
Page 315: ...R e f e r e n c e O n l y ...
Page 316: ...R e f e r e n c e O n l y ...