Reference
Only
HOISTS
18000 SERIVCE/MAINTENANCE MANUAL
5-12
Published 12-05-17, Control # 035-23
Disconnecting Block-Up Limit Control
for the following procedure.
Terminating plug (2, Views A and B) is provided so the block-
up limit control can be disconnected for the following
reasons:
•
Crane setup and rigging
•
Maintenance
If electric cable (3) is terminated, all of the block-up limits (on
boom and jib), the RCL, and the wind speed indicator will be
inactive.
FIGURE 5-9
Item Description
1
Sealing Cap (3 each)
2
Terminating Plug
3
Electric Cable WNE14
4
Electric Cable WBM150 from Cable Reel
5
Boom Node Controller *
6
Sealing Cap (14 each)
7
Terminating Plug (5 each)
8
Wind Speed
9
Digital Output
10
Block Level Switch 1 (Past Production)
11
Block Level Switch 2 (Past Production)
12
Electric Cable from Boom Cable Reel
13
Block-Up Limit (Lower Point – Boom or Jib)
14
Block-Up Limit (Upper Point – Boom or Jib)
15
Electric Cable Out to Jib
16
Luffing Jib Max Angle Limit
17
Luffing Jib Max Angle Limit
18
Luffing Jib Min Angle Limit
* An identical controller (less luffing jib angle
receptacles) is mounted on luffing jib point.
1
2
1
1
2
1
9
8
11
15
1
1
14
13
2
1
7
7
6
6
5
View A
View B
4
3
4
View C
6
7
6
7
6
7
6
16
17
18
WNE14
3
Node 8 on
Boom Butt
Node 7 on
Adapter Frame
WN18
WNE08
12
10
18CSM5-110
Summary of Contents for 18000
Page 1: ...R e f e r e n c e O n l y Service Maintenance Manual Manitowoc 18000 ...
Page 2: ...R e f e r e n c e O n l y ...
Page 4: ...R e f e r e n c e O n l y THE ORIGINAL LANGUAGE OF THIS PUBLICATION IS ENGLISH ...
Page 210: ...R e f e r e n c e O n l y NOTES SKETCHES AND PHOTOGRAPHS ...
Page 315: ...R e f e r e n c e O n l y ...
Page 316: ...R e f e r e n c e O n l y ...