Reference
ELECTRIC SYSTEM
18000 SERIVCE/MAINTENANCE MANUAL
3-12
Published 12-05-17, Control # 035-23
34-P
DO-16
Drum 2 Pump Control – Raise
See
for Values
CAN33-2-128
34-R
DO-15
Drum 2 Pump Control – Lower
for Values
CAN33-2-64
34-S
DO-18
Drum 1/3 (opt.) Pump Control – Lower
See
for Values
CAN33-3-2
34-T
Ground
Left Track Pump Control – Forward
Ground
34-U
DO-19
Left Track Pump Control – Forward
See
for Values
CAN33-3-4
34-V
Ground
Left Track Pump Control – Reverse
Ground
34-W
DO-20
Left Track Pump Control – Reverse
See
for Values
CAN33-3-8
34-X
Ground
Swing 1 Pump Control – Left
Ground
34-Z
DO-21
Swing 1 Pump Control – Left
See
for Values
CAN33-3-16
34-a
Ground
Swing 1 Pump Control – Right
Ground
34-b
DO-22
Swing 1 Pump Control – Right
for Values
CAN33-3-32
34-g
Ground
Jumper to Node Select 2
0 Volts (With Jumper)
34-j
NS-2
Node Select Jumper to Ground
0 Volts (With Jumper)
J6
Receptacle – Drum 3 Controls
36-A
Ground
Drum 3 Motor Control
Ground
36-B
DO-7
Drum 3 Motor Control
See
for Values
CAN33-1-64
36-C
Ground
Drum 3 Brake Solenoid
Ground
36-D
DO-8
Drum 3 Brake Solenoid
See
for Values
CAN33-1-128
36-E
Ground
Pump Drive Cooler Pressure
Ground
36-F
DO-9
Pump Drive Cooler Pressure
0 Volts Off; 24 Volts On
CAN33-2-1
36-G
Ground
Drum 3 Minimum Bail Limit Switch
Ground
36-H
DO-10
Drum 3 Minimum Bail Limit Switch
0 Volts Off; 24 Volts On
CAN33-2-2
36-J
DI-8
Drum 3 Minimum Bail Limit Switch
0 Volts Off; 24 Volts On
CAN59-1-128
36-L
NS-2
Node Select 2 Jumper to Ground
0 Volts (With Jumper)
36-U
Ground
Jumper to Node Select
Ground
36-V
5 Volts
Drum 3 and 5 Motor Speed Sensor
0 to 5 Volts
36-W
Ground
Pump Drive Temperature Sender
Ground
36-X
28 Volts
Pump Drive Temperature Sender
28 Volts Nominal
36-Z
Ground
Drum 5 Motor Speed Sensor
Ground
36-a
AI-9
Pump Drive Cooler Pressure
1 Volt at 0 psi;
5 Volts at 200 psi
CAN6-2
1
36-b
AI-10
Pump Drive Temperature Sender
32.5K ohms at 0
o
C;
680 ohms at 90
o
C
CAN6-4
1
36-j
Ground
Drum 3 Motor Speed Sensor
Ground
36-n
ENC-1A
Drum 3 Motor Speed Sensor
1.2 or 3.2 Volts Not
Moving; 2.2 Volts Moving CAN58-2
2
36-p
ENC-1B
Drum 3 Motor Speed Sensor
1.2 or 3.2 Volts Not
Moving; 2.2 Volts Moving CAN58-2
2
36-r
ENC-2A
Drum 5 Motor Speed Sensor
1.2 or 3.2 Volts Not
Moving; 2.2 Volts Moving CAN58-4
2
36-s
ENC-2B
Drum 5 Motor Speed Sensor
1.2 or 3.2 Volts Not
Moving; 2.2 Volts Moving CAN58-4
2
1
– Lower four bits are the most significant bit of the analog value.
2
– The number in the indicated bank should increase with device rotation and decrease with rotation in opposite direction.
Can ID. No.
Function
Type
Description
Test Voltage
Packet No.
Summary of Contents for 18000
Page 1: ...R e f e r e n c e O n l y Service Maintenance Manual Manitowoc 18000 ...
Page 2: ...R e f e r e n c e O n l y ...
Page 4: ...R e f e r e n c e O n l y THE ORIGINAL LANGUAGE OF THIS PUBLICATION IS ENGLISH ...
Page 210: ...R e f e r e n c e O n l y NOTES SKETCHES AND PHOTOGRAPHS ...
Page 315: ...R e f e r e n c e O n l y ...
Page 316: ...R e f e r e n c e O n l y ...