ELECTRIC SYSTEM
18000 SERIVCE/MAINTENANCE MANUAL
3-16
Published 12-05-17, Control # 035-23
54-H
DO-14
Drum 6 Pump Control – Lower
See
for Values
CAN38-2-32
54-K
Ground
Drum 4A Pump Control – Lower
Ground
54-L
Ground
Drum 4A Pump Control – Raise
Ground
54-M
DO-17
Drum 4A Pump Control –Raise
for Values
CAN38-3-1
54-N
Ground
Pump Drive Cooler 1
Ground
54-P
DO-16
Pump Drive Cooler 1
0 Volts Off; 24 Volts On
CAN38-2-128
54-S
DO-18
Drum 4A Pump Control – Lower
for Values
CAN38-3-2
54-T
Ground
Drum 4B Pump Control – Raise
Ground
54-U
DO-19
Drum 4B Pump Control – Raise
for Values
CAN38-3-4
54-V
Ground
Drum 4B Pump Control – Lower
Ground
54-W
DO-20
Drum 4B Pump Control – Lower
for Values
CAN38-3-8
54-X
Ground
Swing 2 (optional) Pump Control – Left
Ground
54-Z
DO-21
Swing 2 (optional) Pump Control – Left
for Values
CAN38-3-16
54-a
Ground
Swing 2 (optional) Pump Control – Right
Ground
54-b
DO-22
Swing 2 (optional) Pump Control – Right
for Values
CAN38-3-32
54-c
Ground
Pump Drive Cooler 2
Ground
54-d
DO-23
Pump Drive Cooler 2
0 Volts Off; 24 Volts On
CAN38-3-64
54-e
Ground
Accessory System Proportional Solenoid
Ground
54-f
DO-24
Accessory System Proportional Solenoid
0 Volts Off; 24 Volts On
CAN38-3-128
54-g
Ground
Jumper to Node Select 4
Ground
54-m
NS-4
Node Select Jumper to Ground
0 Volts (With Jumper)
J6
Receptacle – Limits
56-A
Ground
Drum 6 Pressure Sender
Ground
56-B
DO-7
Drum 6 Pressure Sender
0 Volts Off; 24 Volts On
CAN38-1-64
56-C
Ground
Drum 4 Pressure Sender
Ground
56-D
DO-8
Drum 4 Pressure Sender
0 Volts Off; 24 Volts On
CAN38-1-128
56-E
Ground
Maximum Boom Angle Limit Switch
Ground
56-F
DO-9
Pump Case Heat Control
0 Volts Off; 24 Volts On
CAN38-2-1
56-G
Ground
Swing/Travel Alarm
Ground
56-H
DO-10
Swing/Travel Alarm
0 Volts Off; 24 Volts On
CAN38-2-2
56-J
DI-8
Maximum Boom Angle Limit Switch
0 Volts Off; 24 Volts On
CAN69-1-128
56-N
NS-4
Node Select 4 Jumper to Ground
0 Volts (With Jumper)
56-R
24 Volts
Maximum Boom Angle Limit Switch
24 Volts
56-U
Ground
Jumper to Node Select 4
0 Volts (With Jumper)
56-V
5 Volts
Drum 4 Motor Speed Sensor
5 Volts DC
56-W
Ground
Pump Case Heat Control
Ground
56-a
AI-9
Drum 6 Pressure Sender
1 Volt at 0 psi;
5 Volts at 7,500 psi
CAN26-2
1
56-b
AI-10
Drum 4 Pressure Sender
1 Volt at 0 psi;
5 Volts at 7,500 psi
CAN26-4
1
56-j
Ground
Drum 4 Motor Speed Sensor
Ground
Can ID. No.
Function
Type
Description
Test Voltage
Packet No.
Summary of Contents for 18000
Page 1: ...R e f e r e n c e O n l y Service Maintenance Manual Manitowoc 18000 ...
Page 2: ...R e f e r e n c e O n l y ...
Page 4: ...R e f e r e n c e O n l y THE ORIGINAL LANGUAGE OF THIS PUBLICATION IS ENGLISH ...
Page 210: ...R e f e r e n c e O n l y NOTES SKETCHES AND PHOTOGRAPHS ...
Page 315: ...R e f e r e n c e O n l y ...
Page 316: ...R e f e r e n c e O n l y ...