5.14 Cold Water Overflow Indication
The yellow LED is used for cold water tank overflow.
Overflow is indicated by a STEADY ON LED, whenever the overflow level is detected.
Should the cold-water tank overflow into the soil line the water overflow YELLOW LED will illuminate.
5.15 Additional Faults not detected by micro-processor
These are faults that may occur which the micro-processor cannot detect (however, it may indicate a fault with the following
conditions).
Not washing bedpans
1.
Check that the cold-water pump is working.
2.
Check that there is cold water in the tank.
3.
Check sprays.
4.
Check bedpan position in door cradle. (Diagram B2)
No power to control box
1.
Check main power.
2.
Check power to control boards.
Leaking water onto the floor
1.
Check all hose fittings.
2.
Check water levels and water probes.
3.
Check pump seals.
4.
Check door seal.