EN | 11 | ACX120/220 | Product description
© MAHLE
8
New oil bottle
9
Service hose
DO NOT USE THE UNIT
UNLESS THE CHARGING
HOSES (HP – LP) ARE
CORRECTLY CONNECTED
Fig. 2: Rear view (detail)
1
Fan
2
Vents
Fig. 3: Right-front view (detail)
1
Power cord connector and
Power switch
2
USB type B (Device port to PC)
3
USB type A (Host port to USB
Memory Stick)
The USB type-A connector
can only be used with USB
2.0 portable memory devices
with Mass storage service for
reports export and station
update, or for connection to
MAHLE refrigerant identifier.
Do not connect other types
of devices, such as USB
keyboards or other units.
Fig. 4: Display and operating unit
1
High-pressure gauge
2
Low-pressure gauge
3
LCD Display
4
Keyboard
The pressure gauges (Fig. 4, Pos. 1, 2) of
the display and operating unit are used to
monitor the pressure during the individual
vehicle A/C service phases. The status of
the various service phases during
maintenance is displayed on the LCD
screen (Fig. 4, Pos. 3).
The menu selection and the necessary
entries are made by way of the keyboard
(Fig. 4, Pos. 4) integrated in the panel.
MAHLE supplies a USB stick for updating
the ACX120/220 software. If required, the
USB stick can be inserted in the USB
type A socket (Fig. 3, Pos. 4) to perform
updating of the
firmware/software.
5.4
User interface
All settings, controls and service
functions are available in the pages
showed in the LCD display moving the
cursor and inserting the data by the
keyboard.
The LCD displays the service equipment’s
status, the progress of A/C system
1
2
2
1
3
1
2
3
4