EN | 14 | ACX120/220 |
© MAHLE
Type
13/18bar
1/4SAE
Trip pressure
18 bar
PED category
(Dir.97/23/EC)
IV
Pneumatic fittings
Net length of
external HP and
LP hoses
3 m
ACX120 HP and
LP pressure
gauges
Analog 80
mm, pulse-
free, 1.6 class
ACX220 HP and
LP pressure
gauges
Analog 80
mm, pulse-
free, 1.0 class
User interface
Display Alphanumeric
al LCD 4x20
Keypad Membrane
Software updating
USB type-A
with USB 2.0
key
USB type-B
with direct
connection to
PC.
Functions and features
Recovery,
exhausted oil
recovery, vacuum,
charge
Auto/Manual
New oil charge
Timed/Manual
Recycling mode
Single or
“Tank
refrigerant
internal
recycling”
Memory for
customized cycle
100 records
Recovered oil
measurement
Manual
Flushing “Regular”
function
(standard)
High intensity
flushing
available with
external
accessory
(option)
A/C Performance
Test
Visual guided
procedure
(with HP and
LP pressure
gauges)
Sound level
< 70 dB (A)
Battery type for
internal Real time
clock
Lithium CR-
2032 3V
180mAh 3g.
Overall dimensions
WxDxH
1050 x 655 x
850 mm
Loadless weight
about 84 kg
Power supply
Frequency 50
Hz
Voltage
230 V ~
Power 800
W
Fuses Retarder
fuses
250V T10A
Installation
category
II
Environmental conditions
Operating
temperature
10-50°C
Humidity 10-90%
R.H.
(non
condensing)
Ambient pressure
75 kPa until
106 kPa