EN | 13 | ACX120/220 | Technical features
© MAHLE
avoid the refrigerant dispersion
in the air during the
disconnection (puff effect);
check possible SCHRADER
valve leaks before disconnection.
To connect the coupling, position the
coupling on the parking coupler, pull
back the knurled section of the
coupling element and press carefully
onto the connection.
6
Technical
features
Cylinders
Cylinder capacity
12 l
Maximum
operating
pressure (PS)
20 bar
ACX120 PED
category
(Dir.97/23/EC)
II
ACX220 PED
category
III
(Dir.97/23/EC)
Weight of
refrigerant content
Scale
Heating band
function
E³ Fill
Safety valve
Type
AIRTEK -
VS14NPT20H
NBRPED4
20bar R 1/4
NPT
Calibration
pressure
20 bar
PED category
(Dir.97/23/EC)
IV
Containers for oil and detection
dye
Recovered PAG
oil container
250 ml
New PAG oil
container
250 ml, with
OIL CARE
valve
Pneumatic circuit
Vacuum pump
flow rate
170 l/min
single stage
Vacuum level
0.02 mbar
Vacuum pump oil
life
60h –
extensible to
max 1000 h
with Pump
Monitoring
System
procedure
Refrigerant
recovery
compressor cubic
capacity
8cc
Drier filter
Every 150Kg of
refrigerant
recovered
Non condensable
gases discharge
Manual, with
solenoid valve
HP and LP taps
Automatic
Safety pressure switch