EN | 22 | ACX120/220 | Manual cycle
© MAHLE
11.1.4
Direct Input
It loads the default parameters of
automatic cycle.
11.2
Automatic cycle data
setting
After selecting the type of A/C system the
main page is shown with the following
preset values (this below is an example):
Amount of refrigerant that will be
charged into the system and the
amount of refrigerant available in the
inner tank of the UNIT.
Charge type: It allows selecting from
which hose the service is carried out,
according to the type of system.
o
Charge from HP hose (red)
o
Charge from LP hose (blue)
o
Charge from HP hose (red)
and LP hose (blue)
o
Charge from HP hose (red)
on the system low pressure
side. Specific for some
Renault models.
Vacuum phase (recommended
values but changeable)
o
Vacuum duration
o
Leak test duration
At the end of the setup, select and
confirm “START” to start the automatic
cycle.
Or press Save if you want to save this
cycle with a name in a My Database
record.
11.2.1
Electric Compressor
Function (Optional)
Before connecting the ACX120/220’s
hoses to the A/C system of the vehicle,
select the Vehicle Compressor Type.
If the selected type is Electric (high
voltage), a special function named
“Electric Compressor Function” will be
executed to clean the hoses from any
previous oil residue.
When the following message appears:
Connect together the LP and HP hoses
by the hoses flushing adapter.
After the connection, select and confirm
“YES” to proceed.
12
Manual cycle
The access to manual cycle can be
achieved selecting the functions in the
following menu.
12.1
Recovery
In the MANUAL CYCLE menu select
RECOVERY function.
Press and start the recovery function and
follow the tool instructions. If there is no
pressure inside the system, this function
cannot be started.