44
48-635 E3 Modulevel
®
Displacer Level Transmitter
TRANSMITTER – ELECTRONICS
(see opposite page)
SPECIFIC GRAVITY AND PROCESS TEMPERATURE
LEVEL RANGE
3.7.2 E3x for Steam Service
E
3
E 3
Standard Construction Electronic MODULEVEL
All Pressures / 9th Digit = 8
600# or below
14
32
48
60
72
84
96
108
120
Inches
356
813
1219
1524
1829
2134
2438
2743
3048
mm
A
B
C
D
E
F
G
H
I
Code
DESIGN TYPE
CHAMBER PRESSURE CLASS
PROCESS CONNECTION SIZE & TYPE
External Cage
Top Mount
Type
1
1
⁄
2
"
2"
3"
4"
6"
A
E
n/a
n/a
n/a
NPT
R
F
n/a
n/a
n/a
SW
P
Q
G
H
K
Flange
ANSI Flange rating
150# RF
300# RF
600# RF
900# RF
1500# RF
√
2500# RF
¬√ƒ
3
4
5
6
7
8
¬
Pressure rating limited by enclosing tube to 5150 psi @ +100°F.
√
For stainless steel construction on 1500# and 2500# models, consult factory.
ƒ
Models E3A and E3B with 2500# construction must have a mounting flange 4" or greater.
MOUNTING AND CHAMBER MATERIALS
Flanged top
¿
Cage side/bottom
Cage side/side
steel
316 SS
steel
316 SS
¡
steel
316 SS
¡
A
B
C
D
E
F
¿
Adjustable 8-foot hanger cable, part number 32-3110-001, required when
distance from flange face to top of displacer must be greater than 7.31".
¡
Bolting material is alloy steel.
Integral
or
Remote
Integral Remote
Integral
or
Remote
Integral
or
Remote
Remote Transmitter Mounting
1 & 4
2
5
2 & 5
3 & 8
6 & 8
Use with
Mounting/Temp.
codes (9th Digit)
Std.
4"
Std.
8"
12"
8"
Temperature Extension
K
B
K
N
E
N
0.55 - 1.09 specific gravity (all pressures)