3.5.3 Mechanical Replacement Parts
3.5.2 User Calibration Procedure
The E3 MODULEVEL is calibrated at the factory, so it normally requires only configuration by the user in the field.
Should the E3 require replacement of any parts in the field, a user calibration must be performed after changing out any of
the following original parts: Bezel assembly, LVDT assembly, range spring, stem assembly, or displacer. The following pro-
cedure should be followed when performing a user calibration in the field. Note: User calibration should be performed at
normal operating conditions. The factory calibration parameters will not be incorporated into the level measurement.
1. Move liquid level on displacer to desired low level point. Using keypad and LCD display, scroll down to DispFact.
2. Press
to access data entry mode, down arrow until “Yes” is displayed and Enter again. The factory menu is now accessible.
3. Scroll down to CalSelct.
4. Press
, then
until “User” is displayed and
again.
5. Press
to UserCalMenu then press
to show the menu.
6. Scroll down to SnrCalLo.
7. Press
, then
and
simultaneously and
again. The current liquid level has been captured as the low level point.
8. Scroll down to LvlCalLo. The default value is 0.00. If a different level value is desired at this point, press
, use the
and
keys to choose the desired value and press
again.
9. Move the liquid level on displacer to the desired high level point. Scroll to SnrCalHi.
10. Press
, then
and
simultaneously and
again. The current liquid level has been captured as the high level point.
11. Scroll down to LvlCalHi. The default value is the displacer length. If a different level value is desired at this point, press
,
use the
and
keys to choose the desired value and press
again. The user calibration is complete.
*
Field replacement of this part requires a user calibration of the repaired unit.
**
For ultra high temperature LVDT stem kits, LVDT core is not included.
Cage
Pressure
Rating
Temp.
Config.
4th digit
Spring SG
Range
E-tube Kits
Stem Kit*
Spring Kits*
CSA,
Carbon Steel
FM, ATEX, IEC
Carbon Steel
CSA, FM,
ATEX, IEC,
316 SS
Inconel
®
316 SS
150#,
300#
& 600#
ANSI
A, B, C
0.23 – 0.54
089-5958-017 089-5958-002
089-5958-006
089-5565-004
089-5340-002
n/a
0.55 – 1.09
089-5565-003
089-5340-005
1.10 – 2.20
089-5565-003
089-5340-008
D, E, F
0.23 – 0.54
089-5958-019 089-5958-004
089-5958-008
089-5565-008
089-5340-003
0.55 – 1.09
089-5565-007
089-5340-006
1.10 – 2.20
089-5565-007
089-5340-009
J, K, L
0.23 – 0.54
089-5958-005 089-5958-001
089-5958-005
089-5565-002
089-5340-002
089-5340-001
0.55 – 1.09
089-5565-001
089-5340-005
089-5340-004
1.10 – 2.20
089-5565-001
089-5340-008
089-5340-007
M, N, P
Temp
≤
+450°F
(+230°C)
0.23 – 0.54
089-5958-018 089-5958-003
089-5958-007
089-5565-006
089-5340-002
n/a
0.55 – 1.09
089-5565-005
089-5340-005
1.10 – 2.20
089-5565-005
089-5340-008
M, N, P
Temp
≥
+500°F
(+260°C)
0.23 – 0.54
089-5958-018 089-5958-003
089-5958-007
089-5565-006
089-5340-003
n/a
0.55 – 1.09
089-5565-005
089-5340-006
1.10 – 2.20
089-5565-005
089-5340-009
900#
ANSI
B
0.55 – 1.09
089-5958-020 089-5958-010
089-5958-014
089-5565-004
089-5340-010
n/a
E
089-5958-022 089-5958-012
089-5958-016
089-5565-008
K
089-5958-013 089-5958-009
089-5958-013
089-5565-002
N
089-5958-021 089-5958-011
089-5958-015
089-5565-006
1500#
& 2500#
ANSI
B
0.55 - 1.09
089-5958-020 089-5958-010
n/a
089-5565-004
E
089-5958-022 089-5958-012
089-5565-008
K
089-5958-013 089-5958-009
089-5565-002
N
089-5958-021 089-5958-011
089-5565-006
150#
THRU
#600
N
0.55 - 1.09
089-5958-027
089-5565-013** 089-5340-011
E
089-5958-028
089-5565-015**
900#
THRU
#2500
N
0.55 - 1.09
089-5958-027
089-5565-014** 089-5340-011
E
089-5958-028
089-5565-016**
For Ultra High Temperature LVDT