106
MPB-311
Conversion
IMPORTANT!
You can modify the locking unit into the "Locked when de-energised"
configuration. You must then parameterise the turnstile for the
"Locked when de-energised" configuration in the "Gate HW" menu.
For parameterisation see separate document "Description of MGC
control unit (Doc.ID: 58170027)".
Characteristic
Rotating freely when de-
energised
Locked when de-energised
Function
The centre pillar can be
rotated in the event of a
power failure. The passage is
free for both directions.
In the event of a power
failure, the passage is
blocked for both directions.
The centre pillar is locked.
Required washers
6 washers:
3 inner, 3 outer
5 washers:
3 inner, 2 outer
Table 10:
Features "rotating freely when de-energised and "locked when de-energised"
Convert locking unit for configuration "Locked when de-energised"
1. Disconnect the pedestrian gate from the power supply. Ensure absence of
voltage. Secure against reactivation.
DANGER
Danger to life, electrical voltage!
2. Open cover.
Mag0088
8a
Fig. 68:
Locking unit configuration "rotating freely when de-energised"