77
MPB-311
Mounting
1. Open the service door with the supplied key.
DANGER
Danger to life if the protective earth conductor for the cover is not connected!
2. Connect the protective earth conductor for the cover at the earthing point of
the support beam.
DANGER
Danger to life if the protective earth conductor for the service door is not
connected!
3. Ensure that the protective earth conductor for the service door is located on
the service door and connected to the cover.
4. Close the service door.
5. Put the cover onto the support beam from the front.
6. Secure the cover with the screws.
7.9
Checking the mounting
Check the following points after mounting:
›
Are all foundation anchors tightened?
›
Are all attachment screws firmly tightened?
›
Is the support beam earthed?
›
Is the support beam closed with the cover?
›
Is the protective ground for the cover connected?
›
Is the protective ground for the service door connected?
›
Is the cover mounted correctly?
›
Is the service door in the cover locked?
Summary of Contents for MPB-311