103
MPB-311
Spare parts and repair
15
Spare parts and repair
15.1
Spare parts
NOTICE
Wrong and faulty spare parts!
Incorrect or defective spare parts can result in damage, malfunctions
or total failure and also impair safety.
›
Use only the manufacturer's original spare parts.
Spare parts can be purchase from your authorised dealer. The address can be found
on your delivery receipt, invoice or on the back of these operating instructions.
Spare part lists can be obtained on request.
15.2
Changing and adjusting proximity sensors
ä
Separate electrical circuit diagram.
The pedestrian passage is equipped with two inductive proximity sensors. These
proximity sensors are used to detect the end position of the centre pillar.
Ma
g00908a
1
2
3
Fig. 65:
Proximity sensors for detecting the end position of the centre pillar
1 Proximity sensor -B1, normally closed (NC)
2 Proximity sensor -B2, normally open
3
Switching cam of the cam plate, countersink marks the home position
The designation of the proximity sensors corresponds to the designation in the
electrical circuit diagram. The proximity sensors are marked with the appropriate
symbol for normally closed or normally open contact.
Summary of Contents for MPB-311