4.2. Setting the IP address and the device name
Static IP address and device name settings must be made for both the main unit side
and the project side.
The main unit side and project side settings are both made by Automation Studio.
4.2.1. Main unit side
Check the following items before making the settings.
・
The number of nodes switch of the X20BC00E3 should be set to “0x00” before
supplying power to the X20BC00E3.
・
The development computer and the X20BC00E3 should be connected.
1.
Add X20BC00E3 under “Profinet (DTM)” on “Physical View” in the Automation
Studio.
* This manual describes the process when using X20CP3585 as a controller, and
X20IF10E1-1 as a PROFINET RT I/F module (master).
Fig 4-6
Automation Studio -- Setting the IP address and the device name (main unit
side) -- No.1
2.
Right-click “Profinet (DTM)” displayed below X20IF10E1-1, and select “Device
Configuration”.
Fig 4-7
Automation Studio -- Setting the IP address and the device name (main unit
side) -- No.2