4.
Press SELECT (D) until DISK OVERLOAD SPD? is
displayed on the upper line.
• The current overload speed is displayed on the
lower line.
NOTE:
Default setting is -300 rpm. Range is -500 to
-100 rpm.
5.
Press left (B) or right (C) arrows to set disc overload
speed. Press SELECT (D).
6.
Press PROGRAM (A) to exit Programming Mode or
press SELECT (D) to proceed to next WINDROWER
SETUP action.
Figure 4.38: Disc Overload Speed
4.4.6
Setting the Hydraulic Overload Pressure
NOTE:
• This procedure requires installation of the optional pressure sensor (MD #B5574). For overload pressure values,
refer to pressure sensor installation instructions (MD #169031).
• To enable sensor, refer to
4.7.2 Switching the Installed Header Sensors On or Off, page 108
1.
Turn ignition key to RUN, or start the engine.
2.
Press PROGRAM (A) and SELECT (C) on cab display
module (CDM) to enter Programming Mode.
• WINDROWER
SETUP?
is
displayed
on
the
upper line.
• NO/YES is displayed on the lower line.
3.
Press right (B) arrow to select YES. Press SELECT (C).
• SET KNIFE SPEED? is displayed.
Figure 4.39: CDM Programming Buttons
147764
85
Revision A