6.
Press and hold FLOAT + button (A) on the CDM.
• CALIBRATING
FLOAT
is
displayed
on
the
upper line.
• FLOAT ( + ) HOLD is displayed on the lower line.
NOTE:
The word HOLD will flash during calibration.
FLOAT (+) DONE will display on the lower line
once calibration is complete.
7.
Release the FLOAT + button (A).
• CALIBRATING
FLOAT
is
displayed
on
the
upper line.
• FLOAT ( - ) HOLD is displayed on the lower line.
Figure 4.27: Positive Header Float
8.
Press and hold FLOAT - button (A) on CDM.
• CALIBRATING
FLOAT
is
displayed
on
the
upper line.
• FLOAT ( - ) HOLD is displayed on the lower line.
NOTE:
The word HOLD will flash during calibration.
HDR FLOAT COMPLETE will display on the
lower line once calibration is complete.
9.
Release FLOAT - button (A).
• TO CALIBRATE SELECT is displayed on the
upper line.
• HEADER FLOAT is displayed on the lower line.
Figure 4.28: Negative Header Float
10. Press right arrow to select next header sensor
calibration or STOP & EXIT. Press SELECT
Refer to
4.3.1 Calibrating the Header Height Sensor,
or
4.3.2 Calibrating the Header Tilt Sensor,
11. Press PROGRAM to exit Programming Mode.