![MacDon M155E4 2016 Manual Download Page 130](http://html1.mh-extra.com/html/macdon/m155e4-2016/m155e4-2016_manual_3215679130.webp)
3.
Press SELECT (B) until DIAGNOSTIC MODE? is
displayed in upper line.
• NO/YES is displayed on the lower line.
4.
Press right (A) arrow to select Yes. Press SELECT (B).
Figure 4.126: Diagnostic Functions
5.
Press SELECT (B) until ACTIVATE FUNCTIONS? is
displayed on the upper line.
• NO/YES is displayed on the lower line.
6.
Press right (A) arrow to select YES. Press SELECT (B).
• ACTIVATE HEADER HT is displayed on the
upper line.
Figure 4.127: Functions
CAUTION
Check to be sure all bystanders have cleared the area.
7.
Press SELECT (E) until KNIFE DRIVE SPD XXXX is
displayed on the upper line.
IMPORTANT:
Do
NOT
over speed the knife drive.
8.
Press and hold HAZARD (C) button.
• Press left (B) arrow to
decrease
knife speed.
• Press right (D) arrow to
increase
knife speed.
Verify the knife drive is functioning properly.
9.
Release the HAZARD (C) button. The knife will stop.
Figure 4.128: Knife Drive
10. Press PROGRAM (A) to exit Programming Mode or
press SELECT (E) to proceed to next ACTIVATE
FUNCTION.
147764
122