4.3.2
Calibrating the Header Tilt Sensor
NOTE:
• The header
MUST
be attached to the windrower to perform this procedure. The cab display module (CDM)
automatically adjusts its programming for each header.
• The engine
MUST
be running to perform this procedure.
1.
Turn ignition key to RUN, or start the engine.
2.
Press PROGRAM (A) and SELECT (C) on cab display
module (CDM) to enter Programming Mode.
• WINDROWER
SETUP?
is
displayed
on
the
upper line.
3.
Press SELECT (C) until CALIBRATE SENSORS? is
displayed on the upper line.
• NO/YES is displayed on the lower line.
Figure 4.21: CDM Programming Buttons
4.
Press right (B) arrow to select Yes. Press SELECT (C).
• TO CALIBRATE SELECT is displayed in upper line
5.
Press left (A) or right (B) arrow until HEADER TILT is
displayed on the lower line. Press SELECT (C).
• HDR TILT SENSOR CAL is displayed on the
upper line.
• EXTEND TILT TO START is displayed on the
lower line.
Figure 4.22: Header Tilt
147764
77