214735
7
Revision A
1017623
A
Figure 1.14: Firewall Extension Module
•
Firewall extension module (A)
Two connectors: P235 and P236
Location: Behind cab, near header lift/fan manifold.
To disconnect, use a small 3
–
6 mm (1/8
–
1/4 in.) blade
screwdriver to insert into the connector
’
s locking tab.
Gently pry upward (no more than 6 mm [1/4 in.]) to unlock
the connector tab, and then pull the connector away from
the module.
1017624
A
Figure 1.15: Chassis Extension Module
•
Chassis extension module (A)
Two connectors: P247 and P248
Location: Under cab, inside left frame rail
To disconnect, use a small 3
–
6 mm (1/8
–
1/4 in.) blade
screwdriver to insert into the connector
’
s locking tab.
Gently pry upward (no more than 6 mm [1/4 in.]) to unlock
the connector tab, and then pull the connector away from
the module.
1019753
A
B
C
C
Figure 1.16: Engine Control Module
•
Engine Control Module (ECM)
Two connectors for Cummins: P100 (A) and J1 Cummins
Proprietary ECM Connector (B)
Location: On engine
To disconnect, pull the rubber boot off the cover, unlock
the latch, and undo the main over-center latch. Remove
strain relief bolts (C) so the connectors can be pulled
away from the ECM.
IMPORTANT:
Be sure to disconnect both connectors. Note connector
locations.
IMPORTANT:
Be sure to reconnect connectors in the proper locations.
Do
NOT
cross connect.