8-6
Stinger®
Administration Guide
Watchdogs, Alarms, and Traps
Defining alarms
remote-shelf-state-change
—A remote shelf changes
state. The new status is shown in the
remote-shelf-
oper-state
setting of the
remote-shelf-stat
profile.
over-temperature-relay
—Temperature threshold has
been crossed.
external-fan-failure
—A sensor on a remote shelf
indicates fan failure.
door-open
—A sensor on a remote shelf indicates that
the door has been opened. The status is shown in the
door-open
setting of the
remote-shelf-stat
profile.
physical-address
Physical address of the entity that is being monitored by
this alarm, as defined by its shelf, slot number, or item-
number. The
physical-address
parameter applies only to
line-state-change
or
slot-state-change
events.
action
Subprofile that specifies the actions that the Stinger unit
performs when it detects the event specified by the
event
parameter. Set the following parameters.
action:
alarm-led-major
Enable/disable the MAJOR alarm status light to illuminate
when the system detects the specified event. Set to
on
to
enable. The default setting is
off
.
action:
alarm-led-minor
Enable/disable the MINOR alarm status light to illuminate
when the system detects the specified event. The default
setting is
off
.
action:
alarm-relay-major
Enable/disable the relay for the MAJOR alarm
relay circuit
to close or open when the system detects the specified
event. If set to
on
, the major alarm relay closes (if it is
normally open) or opens (if it is normally closed) when the
system detects the specified event. The default setting is
off
.
action:
alarm-relay-major-
duration
Number of seconds that the Stinger unit leaves
alarm-
relay-major
in the position specified in the
alarm-relay-
major
action. The default setting of zero (
0
) directs the
system to leave the alarm set indefinitely.
action:
alarm-relay-minor
Enable/disable the relay for the MINOR alarm
relay circuit
to close or open when the system detects the specified
event. If set to
on
, the minor alarm relay closes (if it is
normally open) or opens (if it is normally closed) when the
system detects the specified event. The default setting is
off
.
alarm-relay-minor-
duration
Number of seconds that the Stinger unit leaves
alarm-
relay-minor
in the position specified in the
alarm-relay-
minor
action. The default value
0
(zero) directs the Stinger
unit to leave the alarm set indefinitely.
Parameter
Setting
Summary of Contents for Stinger
Page 1: ...Stinger Administration Guide Part Number 7820 0712 008 For software version 9 7 0 August 2004 ...
Page 4: ......
Page 16: ......
Page 18: ......
Page 62: ......
Page 82: ......
Page 96: ......
Page 182: ......
Page 218: ......
Page 236: ......
Page 252: ......
Page 288: ......
Page 350: ......
Page 362: ......
Page 374: ......