Diagnostic Testing
Testing DSL copper loops
Stinger®
Administration Guide
12-33
To stop the test:
admin>
deisolate 1 5
Multiport tone generation test
By connecting an external test tone generator to the external or auxiliary port on the
CLT module or PSM, you can activate a multiport tone generation test by using the
line-tests
profile or
gen-tone
command.
Using the
line-tests
profile
The following sample commands apply a test tone to ports 3 through 5 of a LIM in
slot 5 using a tone generator connected to the auxiliary terminals of the CLT module:
admin>
set start = 3
admin>
set end = 5
admin>
set test-type = tone-gen
admim>
set test-terminal = auxillary-tester-terminal
admin>
set activate = yes
admin>
write
LINE-TESTS/{ shelf-1 slot-5 0 } written
To perform the same test on ports 3 and 9, proceed as follows:
admin>
set specific-ports = yes
admin>
set port-activation 3 = yes
admin>
set port-activation 9 = yes
admin>
set test-type = tone-gen
admim>
set test-terminal = auxillary-tester-terminal
admin>
set activate = yes
admin>
write
LINE-TESTS/{ shelf-1 slot-5 0 } written
To stop either test, proceed as follows:
admin>
set activate-test = no
admin>
write
Using the
gen-tone
command
You can use the
gen-tone
command to apply test tones on either a range of ports or a
list of individual ports. Its syntax is as follows:
For a range of ports:
gen-tone
shelf slot
ext|aux
startport
-
endport
For individual ports:
gen-tone
shelf slot
ext|aux
p1 p2
......
To deactivate the test:
degen-tone
shelf slot
For example, to connect test tones to ports 3 through 5 on a LIM in slot 5 using the
auxiliary port:
Summary of Contents for Stinger
Page 1: ...Stinger Administration Guide Part Number 7820 0712 008 For software version 9 7 0 August 2004 ...
Page 4: ......
Page 16: ......
Page 18: ......
Page 62: ......
Page 82: ......
Page 96: ......
Page 182: ......
Page 218: ......
Page 236: ......
Page 252: ......
Page 288: ......
Page 350: ......
Page 362: ......
Page 374: ......