Diagnostic Testing
OAM testing
Stinger®
Administration Guide
12-11
OAM: CC was activated or is being stopped by another application
use oam -e 18 2 0 4 for more information
F4-E2E(83b99ba0:3505.0.4) loop(Tx=0, Rx=0)
83b99ba0:F=NORMAL CC(R=NONE:G=ACTIVE M=STOP A=DEACTG D=MON)
In the preceding example, the activation/deactivation status reported by the
A
field
shows that the status is deactivating
Running F4 and F5 continuity tests using the
oam
command
To run a continuity test from a control module, use the following syntax:
oam -C
slot port vpi
|
-c
slot port vpi
[
vci
]
e
|
s +
|
-
You can also run a continuity test from a LIM by first opening a session with the LIM.
When you run a continuity test from a LIM, the
slot
option no longer applies.
The
oam - c | C
+ command starts a continuity check and
oam -c | C
stops the
continuity check on an F5 (
oam -c
) or F4 (
oam -C
) flow. When the continuity test is
started, the continuity check direction is set to A-to-B (the Stinger generates
continuity check cells to the remote peer). When the test is stopped, the continuity
check direction is reset to default.
The following sample command entered on the control module starts a segment
continuity check test on port 18, slot 2, VPI 0, VCI 100:
admin>
oam -c 18 2 0 100 s +
Sending OAM continuity activation cell
Note that the continuity check direction for this continuity check is now set to A-to-B
(Stinger unit to the remote peer), and remains in the A-to-B direction until you stop
the test using the
oam
command, as in the example below:
admin>
oam -c 18 2 0 100 s -
Sending OAM continuity deactivation cell
Note that the continuity check direction for this continuity check is now set to
default.
The following sample command entered on the control module starts an end-to-end
continuity check test on port 17, slot 2, VPI 0:
admin>
oam -C 17 2 0 e +
Sending F4 OAM continuity activation cell
The following command stops the preceding test:
admin>
oam -C 17 2 0 e -
Sending F4 OAM continuity deactivation cell
The following sample command entered on the control module starts an F5 end-to-
end continuity check test on port 17, slot 2, vpi 0, vci 35:
admin>
oam -c 17 2 0 35 e +
The following command stops the preceding test:
admin>
oam -c 17 2 0 35 e -
The following sample command entered on the control module starts an F5 end-to-
end continuity check test on port 17, slot 2, VPI 0, VCI 35:
admin>
oam -C 17 2 0 35 e +
Summary of Contents for Stinger
Page 1: ...Stinger Administration Guide Part Number 7820 0712 008 For software version 9 7 0 August 2004 ...
Page 4: ......
Page 16: ......
Page 18: ......
Page 62: ......
Page 82: ......
Page 96: ......
Page 182: ......
Page 218: ......
Page 236: ......
Page 252: ......
Page 288: ......
Page 350: ......
Page 362: ......
Page 374: ......