255-700-243
6-63
PacketStar
®
PSAX 12-Port Medium-Density DS1 Multiservice Module User Guide
, Issue 1
Release 8.0
Chapter 6 Configuring the Interfaces Using the AQueView
®
EMS
Configuring the Circuit Emulation Interface
DownStream Inter-
working
Default:
TrunkCond
Range: N/A
Format: predefined
alphanumeric
Trunk conditioning will be done with ATM net-
work. The PSAX system will generate an idle data
pattern in the payload of ATM cells to send a sig-
nal to indicate a connection failure.
Unsupp
No interworking will be done with ATM network.
The PSAX system will not send a signal to indi-
cate a connection failure. Do not choose this
value if you want to enable trunk conditioning.
OAM
OAM interworking will be done with ATM net-
work. The PSAX system will use ATM OAM cells
to send a signal to indicate a connection failure.
You can use this value if all the ATM switches
along the connection support ATM OAM cells.
You must use this value if you selected
Unframed1s
in the UpStrmIntrworking field on
the Port and Channel Configuration window of
the module you are configuring. The PSAX sys-
tem does not support upstream interworking of
unframed 1s with a downstream setting of trunk
conditioning.
[Admin Status]
(display only)
Default:
OutOfService
Range: N/A
Format: Predefined
Indicates whether the interface is configured and
brought into service or not.
OutOfService
The interface is not configured and brought into
service.
InService
The interface is configured and brought into ser-
vice.
[Oper Status]
(display only)
Default:
OutOfService
Range: N/A
Format: predefined
alphanumeric
Indicates whether any condition is preventing the
interface from passing traffic.
OutOfService
Indicates that a condition is preventing the inter-
face from passing traffic.
InService
Indicates that no condition is preventing the
interface from passing traffic.
Local NSAP Address
(Hex)
Default:
Hexadecimal
Range: N/A
Format: Hexadecimal
The ATM NSAP address of the local end of the
connection, in hexadecimal notation. Enter the
NSAP address of the local ATM interface.
Table 6-12. Field Descriptions for the Circuit Emulation Interface Configuration Window
Field Names
Field Values
Description
Summary of Contents for PacketStar PSAX
Page 24: ...Part 1 General ...
Page 25: ......
Page 44: ...Part 2 Console Operation ...
Page 45: ......
Page 182: ...Part 3 AQueView Operation ...
Page 183: ......
Page 404: ......
Page 405: ...Part Number 534M0A8001D1 Copyright 2002 Lucent Technologies All rights reserved ...