SAFETY PROCEDURES 

Important safety information is reported on the product and in this manual. Read this installation manual carefully before instal-

ling the unit. 

This document contains additional important instructions for correct installation. 

Symbols used  

indicates prohibited actions  

indicates mandatory actions  

indicates precautions 

 (includes hazards / warnings) 

Explanation of guidance 

HAZARD 

indicates that the item will cause death or serious injury if used incorrectly  

WARNING  

indicates that the item could cause death or serious injury if used incorrectly  

CAUTION 

indicates that the item may cause injury or damage to property, furniture or pets if the instructions are not followed 
carefully  

 General notes 
 

• 

This document should be read carefully and retained for future reference. 

• 

Before carrying out any repairs or maintenance, a risk assessment must be carried out and appropriate measures taken to ensure the 

safety of all personnel. 

• 

All work on the equipment must be carried out by qualified personnel. 

• 

The power supply must be suitable for the supplied equipment. 

• 

The refrigerant, temperature and pressure must comply with the information on the air cooler nameplate. 

• 

Since the exchanger is supplied indirectly, the manufacturer is not aware of the actual application. 

• 

If the equipment is used in the food industry, the end user is responsible for meeting hygiene requirements. 

• 

Install the cooler in accordance with national regulations for cooling and electrical system installation procedures. 

• 

The heat exchanger is suitable for use with the refrigerants indicated on the datasheet or the order documents. The maximum allowa-

ble pressure (design pressure - PS) is shown on the nameplate. The design pressure (PS) must not be exceeded during normal opera-

tion. 

• 

LU-VE heat exchangers are not generally equipped with a high pressure exhaust valve. The installer is responsible for installing the 

high pressure exhaust valve on the system in which the heat exchanger is used. 

• 

The use of the heat exchanger for applications and purposes other than those for which it was designed by LU-VE is not permitted. 

Liability 

The manufacturer shall not accept liability and the warranty for the unit shall be considered void for damage resulting from: 

• 

Incorrect installation; including failure to follow the instructions in the appropriate manuals. 

• 

Modification of or faults in the electrical or refrigerant or water connection. 

• 

Use of the unit under conditions other than those indicated. 

Unit management  

 

Adequate personal protective equipment must be used. 

 

Inspect the equipment for damage caused by incorrect handling or transportation: submit an immediate complaint to the carrier.  

 

Dispose of the packaging material in accordance with local requirements.  

 

Checks on delivery 

All finned coils have been subjected to pressure testing with dry air, then sealed and supplied in a state of slight overpressure. 

Before installation, check there are no leaks using a Schrader valve.  

 

Use appropriate equipment when lifting the unit (e.g. lifting device, trolleys, etc.).  

 

Do not step on or place anything on the external unit. This could cause injury or damage to the unit.  

 Installing the units 

 

Installation must be performed by a qualified installer. Do not install in a location: 

Where access for installation and maintenance is difficult. 

• 

Too close to heat sources. 

• 

That may increase the vibration of the unit. 

• 

That cannot support the weight of the unit. 

• 

Subject to risk of exposure to combustible gas. 

• 

Exposed to oils and vapours. 

• 

With unusual environmental conditions. 

Choose a place: 
 

• 

Where the noise and exhaust air are within the limits permitted by applicable standards and regulations. 

• 

Protected from headwinds. 

• 

With the required space. 

• 

That will not block passageways or doors. 

• 

With a floor structure that is strong enough to support the weight of the unit and minimize vibration transmission. 

ENGL

IS

H

 

Summary of Contents for F27HC

Page 1: ...TUNGSLUFTK HLER F R K HL UND GEFRIERR UME Instrucciones de mantenimiento y montaje para AEROEVAPORADORES PARA C MARAS FRIGORIFICAS F27HC La lingua ufficiale del documento l inglese le altre si intendo...

Page 2: ...urs distributeurs il faut obligatoirement 1 L intervention de personnel qualifi 2 S assurer que le circuit d alimentation est ferm absence de pression 3 Lors de la soudure s assurer que la flamme est...

Page 3: ...lore LU VE non sono generalmente dotati di valvola di scarico ad alta pressione L installatore responsabile del montaggio della valvola di scarico ad alta pressione sul sistema nel quale viene utilizz...

Page 4: ...LETTRICI Tutti i collegamenti elettrici sul campo sono a carico dell installatore PERICOLO Le scosse elettriche possono causare gravi lesioni personali o morte Queste operazioni sono eseguite solo da...

Page 5: ...ati adeguati dispositivi di protezione individuale Le operazioni di manutenzione straordinaria devono essere eseguite da personale appositamente addestrato Scollegare l alimentazione di rete prima di...

Page 6: ...xhaust valve The installer is responsible for installing the high pressure exhaust valve on the system in which the heat exchanger is used The use of the heat exchanger for applications and purposes o...

Page 7: ...ical connections are the responsibility of the installer HAZARD Electric shock can cause serious bodily injury or death These operations must only be performed by qualified personnel WARNINGS This uni...

Page 8: ...E CAUTION Adequate personal protective equipment must be used Non routine maintenance operations must be carried out by specially trained personnel Disconnect the mains power before performing any mai...

Page 9: ...pass e Les changeurs de chaleur LU VE ne sont g n ralement pas quip s de clapet de d charge haute pression Le monteur est respon sable de monter un clapet de d charge haute pression sur le syst me da...

Page 10: ...ous les branchements lectriques sur le lieu d installation sont la charge du monteur DANGER Les d charges lectriques peuvent entra ner de graves blessures corporelles voire la mort Seul un personnel q...

Page 11: ...aud ou endommag Bruit anormal durant le fonctionnement D clenchement fr quent des dispositifs de protection Odeur anormale type odeur de br l ASSISTANCE ET ENTRETIEN ATTENTION S assurer que les quipem...

Page 12: ...her LU VE sind nicht allgemein mit einem berdruckventil ausgestattet Der Installateur ist f r die Montage des ber druck an dem System verantwortlich in dem der W rmetauscher verwendet werden soll Die...

Page 13: ...oren k nnen Verletzungen an den Fingern verursachen Die Ventilatoren nie ohne Schutzgitter bet tigen und acht geben wenn weite oder aufgekn pfte Gew nder getragen werden Vor jedwedem Wartungseingriff...

Page 14: ...ngemessene pers nliche Schutzausr stung benutzt wird Die au erordentlichen Wartungsarbeiten m ssen von entsprechend geschultem Personal ausgef hrt werden Vor jeder Wartungsarbeit bzw vor jedem Hantier...

Page 15: ...calor LU VE no suelen estar dotados de v lvula de alivio de presi n alta El instalador es el responsable del montaje de la v lvula de alivio de presi n alta en el sistema en el cual se utilice el int...

Page 16: ...n son a cargo del instalador PELIGRO Las descargas el ctricas pueden causar lesiones personales graves o incluso la muerte Estas operaciones deber realizarlas exclusivamente personal cualificado ADVE...

Page 17: ...quipos de protecci n individual adecuados Las operaciones de mantenimiento extraordinario deber llevarlas a cabo personal adecuadamente formado al respecto Desconectar la alimentaci n el ctrica antes...

Page 18: ...18 PS PS LU VE LU VE...

Page 19: ...19 2006 42 2014 30 PED 2014 68 III...

Page 20: ...20...

Page 21: ...rmettre l eventuel remplacement des r sistanc es lectriques de d givrage Fig 3 Vor dem Anheben der Ger te die strukturelle Vollst ndigkeit der Hebevorrich tungen und ihre korrekte Befestigung an der S...

Page 22: ...enti Rimuovere la copertura di protezione M passare i cavi negli appositi passa cavi N fissarli serrando il corrispondente pressacavo P e collegare secondo gli schemi indicati sulla copertura di prote...

Page 23: ...for correct system operation N B Keep the superheat as low as possible to obtain maximum unit cooler performance Relever les temp ratures et pressions suivantes Ts T mperature de la chambre froide da...

Page 24: ...cuito de alimentaci n est abierto Prima di procedere ai collegamenti elettrici obbliga torio assicurarsi che il circuito elettrico d alimentazione sia aperto Before proceeding with electrical wiring i...

Page 25: ...ilateur Modello L fter Modelo ventilador Assorbimento motore x 1 Motor power consumption x 1 Puissance moteur x 1 Motorleistung x 1 Consumo motores x 1 x 1 50 Hz N 85 W 0 60 A M 86 W 0 61 A S 86 W 1 0...

Page 26: ...e sur l appareil il est imperative de couper l alimentation lectrique sur l vaporateur Vor jeglicher T tigkeit am Verdampfer ist die Stromzuf hrung zu unterbrechen Antes de efectuar cualquier interven...

Page 27: ...alimentation lectrique sur l vaporateur Vor jeglicher T tigkeit am Verdampfer ist die Stromzuf hrung zu unterbrechen Antes de efectuar cualquier intervenci n es necesario desconectar la alimentaci n...

Page 28: ...e the right to make modifications in order to improve the performance or appearance of our products at any time without notice and without any obligation to previous production All technical character...

Reviews: