User Manual - Lesson 3 - Layout & Basic Functions
LT
&
17
EDITOR FOR THE MANUAL FIELD:
zz
NUM
zz
When we need more precision to adjust the channel level, TRITTON has a little editor for the
manual field from the numerical keyboard. For example, when we work with scrollers or moving
lights this tool is very used.
From the Main menu, select the option NUM:
Main SEQ >0
MDFY
n
NUM
n
->
In the display:
C +
>
0
@ - :
To the right of the display are the symbols that indicate us the new functions for the cursor keys.
These functions only are actives when this display are present.
To the left of the display is the command line.
The new functions, for the cursors or arrow keys, are:
Arrow Up,
+
: Permit us add one channel/group of the selected group.
Arrow down,
-
: Permit us eliminate one channel of the selected group.
Arrow right,
:
: Permit us create a channel range.
Arrow left,
@: Permits us assign a level for the selected channels group in the editor. Enter
this level with two digits.
Examples:
•
Select the channel 1 at 75%.
The first entered number is always a channel number.
Press the keys:
1
ß
ß
75 .
In the command line: C 1@75.
•
Select the channels 5-20 at 56%.
Press the keys:
5
à
à
20
ß
ß
56 .
In the command line: C 5:20@56.
•
Select the channels 16, 18, and 20-24 except the 23 at 15%.
Summary of Contents for TRITTON-24
Page 2: ......
Page 6: ...Manual de Usuario Index D LT...
Page 8: ...User Manual Lesson 1 Presentation 2 LT TRITTON 24...
Page 28: ...User Manual Lesson 3 Layout Basic Functions 22 LT...
Page 32: ...User manual Lesson 4 Masters 26 LT...
Page 40: ...User Manual Lesson 5 Main Menu The Sequence 34 LT...
Page 64: ...User Manual Lesson 7 Setup 58 LT...
Page 68: ...User Manual Lesson 8 Test 62 LT...
Page 74: ...User Manual Lesson 11 EXAM Function 68 LT...
Page 77: ......