UnixWare
Manual No. DB11-000030-00
6-5
6
U
N
I
X
W
A
R
E
Adding System Drives
Use the UnixWare diskadd command to add System Drives to the primary
controller and to any secondary controllers. For more information, refer to
the UnixWare documentation on the diskadd utility.
☛
Note
No UnixWare Slice (UNIX file system) can be greater
than 2GB.
To Primary Controller
For the second and third System Drive of the primary controller, specify the
diskadd command as shown below (assuming the Mylex Disk Array
Controller is the first or only disk controller):
# diskadd c0b0t0d1 ##
(
for the second System Drive
)
# diskadd c0b0t0d2 ##
(
for the third System Drive)
To Secondary Controller(s)
For the first and second System Drives of a secondary controller, specify the
diskadd command as shown below (assuming there is no other disk
controller):
# diskadd c1b0t0d0 ##
(for first System Drive of the
second controller)
# diskadd c1b0t0d1 ##
(for second System Drive of the
second controller)
Updating a Previously Installed Driver
To update the controller driver, follow the procedure below:
1. Insert the Software Kit UnixWare (dak) driver diskette in the file
server’s diskette drive.
2. Type the following (match case exactly as shown):
pkgadd -d diskette1 dak
↵
The new controller driver is installed.
Summary of Contents for Mylex PCI Disk Array Controllers Driver
Page 4: ......
Page 6: ......
Page 7: ...2 3 4 5 6 7 8 NetWare Windows XP NET Windows NT Windows 2000 UnixWare Solaris Linux Appendix...
Page 8: ...iv PCI Disk Array Controller Drivers Manual...
Page 12: ...viii PCI Disk Array Controller Drivers Manual...
Page 96: ...Installing the Disk Array Controller Drivers 8 4 PCI Disk Array Controller Drivers Manual...