Installing the Controller into an Existing
NetWare 4.2 System (Service Pack 9)
If NetWare 4.2 (SP9) is already installed and you wish to add a Mylex Disk
Array Controller later, the controller will be a secondary (non-bootable)
controller. After installing the controller hardware and configuring a disk
array, follow the procedure below to add the necessary controller drivers.
1. With NetWare Server 4.2 (SP 9) loaded and running, load the NetWare
program INSTALL.NLM by typing the following at the console
prompt:
: load install
and press Enter.
2. Choose “Driver Options” in the Installation Options menu.
3. Choose “Configure disk and storage device drivers” in the Driver
Options menu.
4. Choose “Select an additional driver” in the Additional Driver Actions
menu.
NetWare scans for controllers that do not have drivers already loaded.
5. At the “Select a driver” box, press Ins to choose to install an unlisted
driver.
6. Insert the DOS-formatted NT4/NW Drivers Software Kit diskette into
the diskette drive.
7. Press F3 to specify the path of the NetWare driver you’re about to
install.
8. Change the path line to read:
A:\netware
and press Enter. NetWare scans for drivers on the floppy diskette in the
specified path.
9. In the “Select a driver to install” box, select the appropriate driver for
your controller:
MDACFSI.HAM | <Controller model number>
10. Select Yes at the confirmation box to install the driver.
11. Press Enter to select the default server boot path.
Summary of Contents for Mylex PCI Disk Array Controllers Driver
Page 4: ......
Page 6: ......
Page 7: ...2 3 4 5 6 7 8 NetWare Windows XP NET Windows NT Windows 2000 UnixWare Solaris Linux Appendix...
Page 8: ...iv PCI Disk Array Controller Drivers Manual...
Page 12: ...viii PCI Disk Array Controller Drivers Manual...
Page 96: ...Installing the Disk Array Controller Drivers 8 4 PCI Disk Array Controller Drivers Manual...