The User Interface
85
Tap in the Max threshold field to display the pop-up numeric keypad screen and enter the
value to be used.
Threshold
This is the detectors working threshold, set after a completed Learn process.
Tap in the Threshold field to display the pop-up numeric keypad screen and enter the value to
be used.
P span threshold
This field is only displayed if the PQ span option is enabled in the Auto-Learn Setup screen. It
is used to set the P span signal threshold (Pmax – Pmin) to be used during inspection.
Tap in the P span threshold field to display the pop-up numeric keypad screen and enter the
value to be used.
Q span threshold
This field is only displayed if the PQ span option is enabled in the Auto-Learn Setup screen. It
is used to set the Q span signal threshold (Qmax – Qmin) to be used during inspection.
Tap in the Q span threshold field to display the pop-up numeric keypad screen and enter the
value to be used.
Phase angle
This is the product compensation angle computed from a Learn process.
Tap in the Phase angle field to display the pop-up numeric keypad screen and enter the value
to be used.
Phase lock
Enabling this option locks the phase angle so that the detector cannot change it during a
Learn process.
Tap in the Phase lock option check box to enable it.
Compensation
This is the product compensation set automatically from a Learn process. It cannot be
manually changed.
Head drive
The level of transmitter power is selected here from a drop down list which provides options of
MAX (maximum) full power, MED (medium) half power and LOW quarter power.
For dry products the level is normally set to MAX.
For difficult products such as metal film or products with a high or non-uniform level of
conductivity, a lower drive setting may achieve a better result.
Tap on the arrow to the right of the field to display the list of options and select the appropriate
one.
Head lock
Enabling this option locks the Head drive setting, thus preventing the detector from changing
it during a Full Learn process.
Summary of Contents for IQ3+ST
Page 2: ......
Page 36: ...Safety First 26 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 43: ...Installation 33 ...
Page 60: ...Installation 50 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 70: ...About the Metal Detector Range 60 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 172: ......
Page 212: ...Operating Instructions 202 THIS IS PAGE INTENTIONALLY LEFT BLANK ...
Page 240: ...Maintenance 230 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 244: ...Glossary 234 THIS PAGE IS INTENTIONALLY LEFT BLANK ...