The User Interface
134
A standard file browser dialog is displayed. Double-tap on the ‘LomaIQ3’, ‘Diagnostics’ and
‘Product’ folders in turn to display the available data files. Then tap on the required file to
select it and tap on the OK button to close the dialog and load the data from the selected file.
The data will initially be displayed in the P,Q v T screen but other screens can be selected as
normal to display the data using the Screen Selection drop down list at the bottom of the
screen.
Tapping on the Capture button will open the standard file browser dialog again for you to
select a different saved file to use.
To go back to using raw data from the detector head rather than from a saved file, select the
Service Options screen, select the Metal Detector option from the Capture drop down list and
then tap on the Capture button to start a new data capture process. Once the process has
completed the new data will be displayed.
Screen Selection
A drop down list is included to provide access to the seven screens described below.
Phase angle
This field displays the maximum and minimum phase angle values captured.
Pmax
This field displays the maximum P channel signal value captured.
Qmax
This field displays the maximum Q channel signal value captured.
Capture / Stop
This button is used to start and stop a data capture process to obtain raw data from the
detector head. The button legend toggles between ‘Capture’, which indicates that the process
has not been started and ‘Stop’, which indicates that the process has been started.
The data capture process consists of passing a sample product pack through the detector
head at the same time as the Capture button is selected. The captured data set will consist of
approximately 200 data points, so the time scale used will depend on the belt speed.
The data is then utilised by each screen as it is selected to show the data in a plot, trace or
graphical format. Tapping on the ‘Capture’ button again whilst in any screen will start a new
data capture process, following which the new data set will be utilised by each screen.
Summary of Contents for IQ3+ST
Page 2: ......
Page 36: ...Safety First 26 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 43: ...Installation 33 ...
Page 60: ...Installation 50 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 70: ...About the Metal Detector Range 60 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 172: ......
Page 212: ...Operating Instructions 202 THIS IS PAGE INTENTIONALLY LEFT BLANK ...
Page 240: ...Maintenance 230 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 244: ...Glossary 234 THIS PAGE IS INTENTIONALLY LEFT BLANK ...