TYPES OF OPERATIONS
Logicube EchoPlus-
NG User’s Manual
40
will be performed and what values each
pass will be written on each of the
passes selected.
5.3.2.2.2 HPA/DCO
This will open the HPA/DCO option for wiping. If
the drive to be wiped has HPA and/or DCO that
needs to be wiped, select
Yes
for the
corresponding option and the HPA and/or DCO
will also be wiped.
5.3.2.2.3 LBA
By default, this is set to 100% which will wipe all
Logical Block Addresses (LBAs) and will wipe the
entire drive (100%).
5.3.2.2.4 Passes
This Wipe Setting will change depending on the
Wipe Pattern
Mode
selected.
If
None
was selected, this is not
selectable.
If
DoD
was selected, all 7 passes will be
pre-filled. Users can edit the pass values
if desired by tapping the
edit
icon.
If
Custom
was selected, one pass will be
pre-filled with a random value. Users
can edit the pass values if desired by
tapping the
edit
icon.
Editing one or more of the passes in DOD or
CUSTOM mode will bring up this screen:
SKIP –
Instructs the EchoPlus-NG to skip
the pass.