Operation
WeftMaster CUT-iT Dornier
www.loepfe.com
25
Cutting wire type 05 (1.5 mm)
Param-
eter
Function
Min.
value
Max.
value
One
unit
Value Unit Description
50
Min. standby current
0.0
2.0
0.1
0.0
A
Smallest adjustable value
51
Max. standby current
1.1
11.0
0.1
10.0
A
Largest adjustable value
52
Standard standby current
0.0
10.0
0.1
1.1
A
Standard value specified in
program
53*
Min. running current
1.1
10.0
0.1
10.0
A
Smallest adjustable value
54
Max. running current
10.0
27.0
0.1
27.0
A
Largest adjustable value
55*
Standard running current
10.0
27.0
0.1
10.0
A
Standard value specified in
program
56
Startup current
10.0
80.0
0.1
70.7
A
Fixed startup current
57
Min. startup time
0.1
1.9
0.1
0.2
s
Shortest adjustable time
58
Max. startup time
0.1
2.0
0.1
1.9
s
Longest adjustable time
Cutting wire type 06 (xx mm)
Param-
eter
Function
Min.
value
Max.
value
One
unit
Value Unit Description
60
Min. standby current
0.0
2.0
0.1
0.0
A
Smallest adjustable value
61
Max. standby current
1.1
11.0
0.1
10.0
A
Largest adjustable value
62
Standard standby current
0.0
10.0
0.1
1.1
A
Standard value specified in
program
63*
Min. running current
1.1
10.0
0.1
10.0
A
Smallest adjustable value
64
Max. running current
10.0
27.0
0.1
27.0
A
Largest adjustable value
65*
Standard running current
10.0
27.0
0.1
10.0
A
Standard value specified in
program
66
Start-up current
10.0
80.0
0.1
70.7
A
Fixed startup current
67
Min. startup time
0.1
1.9
0.1
0.2
s
Shortest adjustable time
68
Max. startup time
0.1
2.0
0.1
1.9
s
Longest adjustable time