Operation
WeftMaster CUT-iT Dornier
www.loepfe.com
23
Cutting wire type 01 (0.5 mm)
Param-
eter
Function
Min.
value
Max.
value
One
unit
Value Unit Description
10
Min. standby current
0.0
2.0
0.1
0.0
A
Smallest adjustable value
11
Max. standby current
1.1
3.2
0.1
2.9
A
Largest adjustable value
12
Standard standby current
0.0
2.9
0.1
1.1
A
Standard value specified in
program
13*
Min. running current
1.1
2.9
0.1
2.9
A
Smallest adjustable value
14
Max. running current
2.9
10.5
0.1
9.6
A
Largest adjustable value
15*
Standard running current
2.9
10.5
0.1
2.9
A
Standard value specified in
program
16
Startup current
2.9
16.0
0.1
12.0
A
Fixed startup current
17
Min. startup time
0.1
1.3
0.1
0.2
s
Shortest adjustable time
18
Max. startup time
0.1
1.5
0.1
1.2
s
Longest adjustable time
Cutting wire type 02 (0.7 mm)
Param-
eter
Function
Min.
value
Max.
value
One
unit
Value Unit Description
20
Min. standby current
0.0
2.0
0.1
0.0
A
Smallest adjustable value
21
Max. standby current
1.1
5.5
0.1
5.0
A
Largest adjustable value
22
Standard standby current
0.0
5.0
0.1
1.1
A
Standard value specified in
program
23*
Min. running current
1.1
5.0
0.1
5.0
A
Smallest adjustable value
24
Max. running current
5.0
15.4
0.1
14.0
A
Largest adjustable value
25*
Standard running current
5.0
15.4
0.1
5.0
A
Standard value specified in
program
26
Start-up current
5.0
24.2
0.1
18.6
A
Fixed startup current
27
Min. startup time
0.1
1.3
0.1
0.2
s
Shortest adjustable time
28
Max. startup time
0.1
1.5
0.1
1.2
s
Longest adjustable time