For All Installations
If the Power, IP Link and IP Monitoring LEDs are lit continuously, and the
alarm test fails:
1.
Verify that the panel is properly connected to the LNI. When armed the
panel should recognize the phone line provided by the LNI.
2.
Verify that the panel is armed and recognizes the phone line. If it does
not, verify the connections from the panel to the LNI.
The IP Link LED Flashes for More than 30 Seconds
If the IP Link LED flashes for more than 30 seconds, it has been unable to
obtain an IP address automatically from the customer’s router. There are a
variety of reasons why this may happen.
1.
Check that the wiring to the customer’s LAN is installed correctly.
2.
Check that the LEDs on the “Internet” jack are lit.
3.
If the LEDs are not lit, check that the RJ45 is fully inserted at both
ends; in the LNI and in the router. Ensure that the router is powered. In very rare
cases, it is possible that the CAT5 cable is faulty. Replace with another cable.
4.
If the LED is lit, the customer’s LAN is not allowing the LNI to obtain
an IP address automatically. A static address must be used. To configure the LNI
2000 with a static address:
5.
Obtain a static IP address from the customer Set up the LNI 2000 on
the customer’s network with this address.
The IP Link LED fails to light
This LED indicates that the LNI has been able to establish and Internet
connection to the LNS. If the LED fails to light, check all of the following:
1.
There may be a mistake in installation, or a connection made
incorrectly. Verify that all installation steps have been followed and that all
connections have been made correctly.
2.
The customer’s network or Internet connection is “down.” Using a PC
connected to the customer’s LAN, verify the network and Internet connection.
(For example, by opening a browser and doing a search at google.com .)
LoBenn Network Interface 2000 Installation Manual
67