Note
: Use These Instructions for
Standard
Installations
Step One: Program the LNI 2000
Note
: LoBenn Inc. strongly recommends that this programming step
be done at the installer’s or alarm center offices, before the
installation visit to the customer’s premises.
Programming may be done by the installer at a home or business office or by the
contracting alarm company.
Programming requires a computer or laptop configured to obtain IP addresses
automatically, information from the LNI Pre-Installation Site Survey and a web
browser.
1.
Connect the LNI 2000 to your PC with a CAT 5/RJ45 Ethernet cable from
the programming port labeled “Local” to an Ethernet port on your PC.
Note:
Your PC should be configured to obtain an IP address
automatically (DHCP client).
2.
Power the LNI 2000 by plugging a 12V DC adapter into the “Power” port
on the LNI 2000. Plug the 12V DC adapter into any 120V socket. The green
“Power” LED on the top of the LNI 2000 will light.
10. Connect to PC for Programming
LNI 2000 Installation Manual
33