This menu item appears only when you are in Tec mode.
2. LOST GAS (only in Tec Mode)
If you have lost a gas that was to be used later for decompression, it is very
important to use this menu option to mark it as “Lost”. This will prevent
this Lost Gas from being used in ascent schedule planning. If you fail to do
this, your ascent schedule will be wrong, as the KAON will assume that
you can still use that gas. The gases will be listed from the one with the
highest content of O2 to the one with the lowest.
EXAMPLE: Let’s say you are planning to use Air and Nx50 on your dive, and let’s say your deco time
would be 30 minutes on Air and only 20 minutes on Nx50. If you were to lose Nx50, but not mark it as
“Lost”, then your KAON would tell you that your total Time To Surface is 20 minutes, because it
would think that you can still use the Nx50. However, as long as you keep your KAON set to Air
throughout your decompression, the KAON will continuously adjust its calculations, and in effect will
keep you decompressing for 30 minutes.
If an alarm is annoying you,
and you are confident that you should continue the violation that is
causing the alarm
, you can switch that alarm off. Choosing the “Silence Alarms” option will cause
ALL of the alarms that are on at that moment to be silenced until the end of the dive.
3. Silence Alarms
Alarms you can silence are:
•
Depth alarm
•
Time alarm
•
Ascent/Descent Rate alarm
Other alarms, i.e. deco ceiling alarm and gas-related alarms cannot be silenced.
For example, if you have exceeded your maximum depth and time alarm settings, both of these alarms
will be on. If you choose to “Silence Alarms”, you will turn both of these alarms off and neither of
them will be displayed on this dive anymore – no matter what depth you go to or how long you stay
there for. However, if you exceed your maximum ascent rate on the same dive, it will still cause an
alarm.
Keep in mind that the descent and ascent rate alarms are the same alarm – if you silence the descent
rate alarm on the way down, you will not see alarm go off if you ascend too fast on the way up!
WARNING
Use of the “Silence Alarms” is intended for exceptional circumstances. Ignoring an alarm you have
chosen to set means you are exceeding the limits of your dive plan and putting yourself at a very
serious risk.