4. Installation
series – Extender Application Mode – User's Manual
45
4. Installation
series – Extender Application Mode – User's Manual
45
EXTENDER APPLIC
A
TION MODE
Applied F-series endpoint firmware package: v2.0.0 | Applied R-series endpoint firmware package: v2.0.0 | LDC software: v2.5.9b3
Required fiber optical equipment for connecting an F110 and an R100 DUO endpoint device
INFO:
This method does not work in case of using
DAC cables
in the F-series endpoint device.
4.7.2. SFP+ to Neutrik opticalCON QUAD
This method is working between the following endpoint models:
F-series endpoint model
R-series endpoint model
UBEX-PRO20-HDMI-F100
UBEX-PRO20-HDMI-R100 2xMM-QUAD
UBEX-PRO20-HDMI-F110
UBEX-PRO20-HDMI-R100 2xSM-QUAD
Connecting Steps
Step 1.
Insert 2 pcs 10GbE singlemode/multimode SFP+ transceiver modules to the SFP+ slots of the F100
/ F110 endpoint device.
Step 2.
You need a singlemode/multimode Neutrik opticalCON QUAD series connector and 2 pcs singlemode/
multimode fiber optical patch cables with LC duplex connectors. Connect the SFP+ modules and the
back of the Neutrik opticalCON QUAD connector by the patch cables (2 pcs standard LC duplex
connectors can be found on the back of the Neutrik opticalCON QUAD connector).
TIPS AND TRICKS:
Extra Neutrik
connectors can be assembled to a blank
1U high rack shelf which can make easier
the mounting of the connectors and the
cabling.
Step 3.
Establish connection between the additional Neutrik opticalCON QUAD connector
and the R100 endpoint device by a singlemode/multimode Neutrik opticalCON
QUAD series cable. The following figure shows
the correct cabling layout of extra QUAD
optical connector
(the rear side of the extra connector can be seen on the right).
ATTENTION!
Always be sure that the fiber optical mode of the entire fiber optical equipment (SFP+
modules, LC patch cables, Neutrik connectors, and cables) and R100 endpoint device are the same.
Connecting to the
2xMM-QUAD
model requires
multimode
equipment, connecting to the
2xSM-QUAD
model
requires
singlemode
equipment.
Required fiber optical equipment for connecting an F110 and an R100 QUAD endpoint device
INFO:
This method does not work in case of using
DAC cables
in the F-series endpoint device.
4.7.3. SFP+ BiDi to Neutrik opticalCON DUO BiDi
This method is working between the following endpoint models:
F-series endpoint model
R-series endpoint model
UBEX-PRO20-HDMI-F100
UBEX-PRO20-HDMI-R100 2xSM-BiDi-DUO
UBEX-PRO20-HDMI-F110
Connecting Steps
Step 1.
Insert 2 pcs 10GbE singlemode SFP+ BiDi transceiver modules to the SFP+ slots of the F100 / F110
endpoint device.
Step 2.
You need a singlemode/multimode Neutrik opticalCON DUO BiDi connector and 2 pcs singlemode/
multimode fiber optical patch cables with LC simplex connectors. Connect the SFP+ modules and
the back of the Neutrik opticalCON DUO connector by the patch cables (a standard LC duplex
connector can be found on the back of the Neutrik opticalCON DUO connector).
TIPS AND TRICKS:
Extra Neutrik
connectors can be assembled to a blank
1U high rack shelf which can make easier
the mounting of the connectors and the
cabling.