7. Programmers’ Reference
series – Extender Application Mode – User's Manual
114
7. Programmers’ Reference
series – Extender Application Mode – User's Manual
114
EXTENDER APPLIC
A
TION MODE
Applied F-series endpoint firmware package: v2.0.0 | Applied R-series endpoint firmware package: v2.0.0 | LDC software: v2.5.9b3
7.7.4. Identify Stream / Identify Display
Calling the method makes generating 10 test colors on the display device for 10 seconds. The feature helps
to identify the stream and the screen itself physically.
Command and Response
#identifystream #identifydisplay
ç
CALL•/MEDIA/VIDEO/
<source
|
out>
:identify()
æ
mO•/MEDIA/VIDEO/
<source
|
out>
:identify
Example
ç
CALL /MEDIA/VIDEO/S1:identify()
æ
mO /MEDIA/VIDEO/S1:identify
Explanation
7.7.5. Resolution Mode Setting - Input Side
Command and Response
ç
SET•/MEDIA/VIDEO/
<source>
.ResolutionMode=
<resolution_mode>
æ
pw•/MEDIA/VIDEO/
<source>
.ResolutionMode=
<resolution_mode>
Parameters
Parameter
Parameter description
Value
Value description
<resolution_mode>
Resolution mode
setting
Pass
Pass-through mode - the original stream is
transmitted.
Forced
The transceiver forces the resolution set in the
ResolutionSetting
for the stream.
Example
ç
SET /MEDIA/VIDEO/S1.ResolutionMode=Forced
æ
pw /MEDIA/VIDEO/S1.ResolutionMode=Forced
7.7.6. Resolution Mode Setting - Output Side
Command and Response
ç
SET•/MEDIA/VIDEO/
<out>
.ResolutionMode=
<resolution_mode>
æ
pw•/MEDIA/VIDEO/
<out>
.ResolutionMode=
<resolution_mode>
Parameters
Parameter
Parameter description
Value
Value description
<resolution_mode>
Resolution mode
setting
Pass
Pass-through mode - the original stream is
transmitted to the sink device.
Forced
The transceiver forces the resolution set
in the
ResolutionSetting
for the stream and
transmits it to the sink device.
EdidBased
The transceiver forces the resolution which
is read out from the EDID of the connected
sink device. The resolution can be queried
from a property - see the details in the next
section.
Example
ç
SET /MEDIA/VIDEO/O1.ResolutionMode=EdidBased
æ
pw /MEDIA/VIDEO/O1.ResolutionMode=EdidBased
7.7.7. Query the EDID Based Resolution
Command and Response
ç
GET•/MEDIA/VIDEO/
<out>
.EdidBasedResolution
æ
pr•/MEDIA/VIDEO/
<out>
.EdidBasedResolution=
<resolution>
Example
ç
GET /MEDIA/VIDEO/O1.EdidBasedResolution
æ
pr /MEDIA/VIDEO/O1.EdidBasedResolution=3840x2160p60
#scaler #frc