Fusion SingleStar Installation Procedures
6-14
InterReach Fusion SingleStar Installation, Operation, and Reference Manual
CONFIDENTIAL
D-620605-0-20 Rev A
2.
Fusion Sin-
gleStar Hub
power is On
and RAUs
are con-
nected
PORT
Off
Check the CATV cable.
Power is not getting to the
RAU.
PORT
Red (60 ppm flashing)
Test the CATV cable. If the cable
tests OK, try another port. If the
second port’s LEDs are Red/Off,
replace the RAU. If the second
RAU doesn’t work; replace the
Fusion SingleStar Hub.
Power levels to the RAU are
not correct; communications
are not established.
If the second port works, flag
the first port as unusable;
replace the Hub when possi-
ble.
Off
PORT
Red
Use AdminBrowser to determine
the problem.
The RAU is off-line.
Table 6-5
Troubleshooting Fusion SingleStar Hub LEDs During Installation
During
Installation
LED
State
Action
Impact