Preparing for System Installation
6-6
InterReach Fusion SingleStar Installation, Operation, and Reference Manual
CONFIDENTIAL
D-620605-0-20 Rev A
Circulator or Duplexer
Installed between the repeater and the Hub uplink and downlink ports
Base Station-to-Fusion SingleStar Configuration (for each Fusion Band)
Base Station
Installed, inspected; verify RF power (see tables in Section 5.2 on page 5-4);
N-male to N-male coaxial cable
Attenuator
Attenuation may be required to achieve the desired RF output at the RAU, and the
desired uplink noise floor level
Circulator or Duplexer
When using a duplex BTS: Installed between the BTS and the Hub uplink and
downlink ports. Not used with a simplex BTS
Connecting LGCell Main Hub(s) to an Fusion SingleStar Hub
5-port Alarm Daisy-Chain Cable
(PN 4024-3)
For contact alarm monitoring: connecting 2 to 21 LGCell Main Hubs to an Fusion
SingleStar Hub. N.C. operation only.
If connecting LGCell to Fusion SingleStar, the Alarm Sense Adapter Cable is
required to connect the daisy-chain cable to Fusion SingleStar.Do not combine
LGCell Main Hubs with Fusion SingleStar Hubs in the same chain.
Alarm Sense Adapter Cable
(PN 4025-1)
Use with 5-port Alarm Daisy-Chain Cable to connect 2 to 21 LGCell Main Hubs
to a Fusion SingleStar Hub; Use alone to connect 1 LGCell Main Hubs to a Fusion
SingleStar Hub.
Connecting Multiple Fusion SingleStar Hubs Together
5-port Alarm Daisy-Chain Cable
(PN 4024-3)
For contact alarm monitoring of fault and warning alarms. Used to feed the alarms
from multiple Fusion SingleStar Hubs into a BTS or MetroReach Focus. N.C.
Operation.
Cabling
Coaxial: repeater, base station,
Smart Source to Fusion Single-
Star Hub
Coax approved; N-type male connectors.
Coaxial: RAU to passive
antennas
Use low-loss cable; N male connector; typical 1 m (3.3 ft) using RG142 coaxial
cable.
CATV
TIA/EIA 568-A and 570-A approved; centerpin F male connectors. CATV cable
must be screened and it must be grounded at both connector ends. The RAU will
be damaged if it is mis-wired.
Tie-off cables to avoid damaging the connectors because of cable strain.
Fusion SingleStar Hub to RAUs
• Minimum: 0 meters (0 ft)
• Maximum: RG-59: 150 meters (472 ft)
RG-8: 170 meters (558 ft)
RG-11: 275 meters (902 ft)