APPENDIX A
Cables and Connectors
A.1
CATV Cable
• Connects the Fusion SingleStar Hub to the RAU(s)
• Transmits multiband (downlink) and receives (uplink) IF signals
• Delivers DC electrical power to the RAUs. The Fusion SingleStar Hub’s DC volt-
age output is 54V DC nominal. A current limiting circuit is used to protect the Hub
if it reaches its current limit
• Carries configuration and status information
• Use shielded F connectors
• Lengths:
RG-59:
• Minimum: 10 meters (33 ft.)
• Maximum: 150 meters (492 ft.)
RG-6:
• Minimum: 10 meters (33 ft.)
• Maximum: 200 meters (656 ft.)
RG-11:
• Minimum: 10 meters (33 ft.)
• Maximum: 300 meters (984 ft.)
NOTE:
Recommended minimum and maximum CATV cable lengths vary
depending upon which CATV cable you use.
The nominal DC impedance of the CATV cable is 0.08 ohm/meter and the nominal
RF impedance is 100 ohm.