Faults and Warnings
4-4
InterReach Fusion SS Installation, Operation, and Reference Manual
CONFIDENTIAL
D-620605-0-20 Rev A
NOTE:
Refer to Section 8 for troubleshooting using the LEDs.
Status LEDs
The RAU status LEDs can be in one of the states shown in Table 4-2. These LEDs
can be:
off
steady green
steady red
There is no off state when the unit’s power is on.
4.3
Faults and Warnings
Both fault and warning conditions are reported to the Fusion SingleStar Hub where
they are stored. Only faults are indicated by LEDs.
For more information, refer to:
• page 8-11 for RAU faults.
• page 8-14 for RAU warnings.
• page 8-17 for RAU status messages.
Table 4-2
Remote Access Unit LED States
LED State
Indicates
Off
Off
• The RAU is not receiving DC power.
Green
Green
• The RAU is powered and is not indicating a fault condition. Communication with the
Fusion SingleStar Hub is normal; however, the system test may need to be performed or a
warning condition may exist (use AdminBrowser to determine this).
Green
Red
• The RAU is indicating a fault or lockout condition, but communication with the Fusion Sin-
gleStar Hub is normal.
Red
Red
• The RAU is reporting a fault or lockout condition and is not able to communicate with the
Fusion SingleStar Hub
LINK
ALARM
LINK
ALARM
LINK
ALARM
LINK
ALARM