- Red LED means error no. 10’s digit, and green LED means 1’s digit, and when red and green
simultaneously blink, it means 100’s unit.
Ex) Inverter compressor IPM defect Error : error number 21
Error Code
Description
LED 1 (Red)
LED 2 (Green)
21
Inverter compressor IPM defect
2times
◑
1time
◑
ZHBW056A0
ZHBW076A0
ZHBW096A0
ZHBW126A0
ZHBW146A0
ZHBW166A0
ZHBW128A0
ZHBW148A0
ZHBW168A0
Error
Code
Description
Main Reasons
21**
DC Peak(IPM Fault)
Inverter compressor drive IPM defect / inverter compressor defect
22**
Max. CT(CT2)
Increase of inverter compressor CT value
23**
DC Link Low Volt.
After inverter activation relay is ON, DC voltage recharge defect
24**
High Pressure Error
High pressure exceeds the limit of high pressure switch
26**
DC Comp Position Error
Inverter compressor error, causing initial activation failure
27**
PFC Fault Error
Error by overcurrent at inverter input
28
DC Link High Volt
After inverter activation relay is ON, DC voltage recharge defect
29**
Comp Over Current
Inverter compressor activation failure or increase of CT value
32**
D-Pipe High(Inv.)
Excessive rise of inverter compressor discharge temperature, causing
compressor OFF
35**
Low Pressure Error
Excessive decrease of low pressure
41**
Inv. D-Pipe Th Error(Open/Short)
Inverter compressor discharge temperature sensor disconnection or
short circuit
43**
High Pressure Sensor(Open/Short)
High pressure sensor disconnection or short circuit of inverter
compressor
44**
Outdoor air Th Error(Open/Short)
Air temperature sensor disconnection or short circuit
45**
Cond. Middle Pipe Th Error
(Open/Short)
Condenser Middle Pipe sensor disconnection or short circuit
46**
Suction Pipe Th Error(Open/Short)
Inverter compressor suction temperature sensor disconnection or short
circuit
47
Const-D-Pipe Sensor Error
Const-D-Pipe Sensor disconnection or short circuit
52****
PCB Communication Error
Checking the communication state between Main PCB and Inverter PCB
53**
Communication Error(PCB(Heater)
÷
PCB(Inverter))
PCB(Heater) unit does not receive signal from PCB(Inverter)
54*
Open and Reverse Phase Error
Prevention of phase unbalance and prevention of reverse rotation of
constant-rate compressor
60**
EEPROM Error(Outdoor)
PCB(Inverter) EEPROM error
61**
Cond. Middle Pipe High
EEV connector diplaced/poor EEV assembly
62**
Heatsink Error(High)
PCB(Inverter) heat generation, causing the rise of heatsink temperature
67**
Fan Lock Error
Outdoor BLDC Fan lock
73**
AC Input Instant over Current Error
Error by overcur’rent detection at inverter input
114**
Injection In TH Error (Open/Short)
Injection In sensor disconnection or shot circuit
115**
Injection Out TH Error (Open/Short)
Injection Out sensor disconnection or shot circuit
Main PCB assembly(Inverter)