- 100 -
Copyright © 2018 LG Electronics Inc. All rights reserved.
Only training and service purposes.
Display
code
Title
Cause of error
Check point & Normal condition
52
Communication Error
(Inverter PCB ↔ Main
PCB)
Checking the communica-
tion state between Main
PCB and Inverter PCB
• Generation of noise source interfering with com-
munication
Items for checking
Sub-items for checking
Resetting
power source
Connector
Insufficient insertion
of housing
Damage of
wire coating
Check the Heat sink
and Chassis Panel
Checking
power source
LED Off
Damage of
wire coating
Replacement of
inverter PCB
Replacement of
main PCB
※ It should not be short
※ Refer to 3.15.1
WARNING
Before checking PCB(Inverter) or each outdoor electric parts, wait for 3 minutes after the power is off. When measuring at standby
state of power supply, after checking the measurement mode of the meter, be careful of the short-circuits with other parts.
• Resetting power source: Wait for 3 minutes after turning the power of the porduct off.