Installer setting
• You can set the product user functions.
• Some functions may not be displayed/operated in some product types.
Test
Description
3 Minutes Delay
Factory use only
Select Temperature Sensor
Selection for setting temperature as air temperature or leaving water
temperature or air+leaving water temperature
Dry Contact Mode setting
Dry contact function is the function that can be used only when the dry contact
devices is separately purchased and installed.
Central Control address
When connecting the central control, set the central control address of the unit.
Pump Test run
Water pump test run
Air cooling set temp. setting
Adjusting range of 'Setting Air Temperature' in cooling mode
Water cooling set temp. setting
Adjusting range of 'Setting Leaving Water Temperature' in cooling mode
Air heating set temp. setting
Adjusting range of 'Setting Air Temperature' in heating mode
Water heating set temp. setting
Adjusting range of 'Setting Heating Flow Temperature' in heating mode
DHW Set Temp.setting
Setting DHW set temperature
Screed drying setting
Setting for using Step 1 or 2 capacity of electric
Heater on temperature
Setting outdoor air temperature where half capacity of electric heater starts
operation.
Water supply off temp. during
cooling setting
Determine leaving water temperature when the unit is turned off. This funtion is
used for preventing condensation on the floor in cooling mode
Tank disinfection setting 1
Setting start/maintain time for pasteurisation
Tank disinfection setting 2
Setting pasteurisation temperature
Tank setting 1
Setting start temperature for operation
Tank setting 2
Setting maintain temperature for operation
Heater priority
Determine electric heater and water heater on and off
DHW time setting
Determine follow time duration : operation time of domestic hot water tank
heating, stop time of domestic hot water tank heating, and delay time of DHW
tank heater operating
Use Heating Tank Heater
Change setting value for hot water tank heater operation such as hot water
tank heater use / unused and heater delay time
TH on/off Variable, heating air
setting
Heating air temperature TH On / Off Type setting
TH on/off Variable, heating Water
setting
Heating Water Outlet Temperature TH On / Off Type