- 71 -
Copyright © 2018 LG Electronics Inc. All rights reserved.
Only training and service purposes.
2.3 Error Code List
CAUTION
Precaution in service or check
Even after stopping the operation of product, it takes some time to discharge the remaining electricity of the
electrolytic capacitor that was charged early. Before conducting a checking or repairing job, pull out the plug out of the
outlet and make sure that the lamp on the control board outdoor unit is off.
• Notice of error code
-
Slight / Heavy / Option Troubles : lowercases ‘ch’ + code no.
- Errors : capital letters ‘CH’ + code no.
- Slight Trouble: *
- Heavy Trouble: **
- Option Trouble: ***
- Error: ****
Main PCB assembly(Heater)
Error
Code
Description
Main Reasons
01 *
Problem in Remote Room Air sensor
Remote room air sensor disconnection or short circuit
02 *
Problem in Refrigerant (Inlet side) sensor
Refrigerant Inlet side sensor disconnection or short circuit
03 ****
Bad communication between control panel and unit Connector connection error or connection wire break
05 **
Bad communication between Indoor unit and Main
PCB assembly(Inverter) and Main PCB
assembly(Heater)
PCB(Heater) Unit does not receive signal from PCB(Inverter)
06 *
Problem in Refrigerant (Outlet side) sensor
Refrigerant Outlet side sensor disconnection or short circuit
08 ***
Problem in Water Tank sensor
Water tank sensor disconnection or short circuit
09 ****
PCB Program (EEPROM) Fault
Electrical or mechanical damage at the EEPROM
13 ***
Problem in Solar-thermal sensor
Solar-thermal sensor disconnection or short circuit
14 ****
Problem in Flow Switch
Folw switch is open while internal water pump is working
15 ****
Water pipe overheated
Leaving water temperature is above 57℃
16 ****
Problems in sensors
An error cord 17,18,19 error has occurred at the same time.
17 *
Problem in Water-inlet sensor
Water-Inlet sensor disconnection or short circuit
18 *
Problem in Water-outlet sensor
Water-outlet sensor disconnection or short circuit
19 *
Problem in Elec/Heater Water-outlet sensor
Problem in Elec/Heater Water-outlet sensor
20 ****
Electric heater overheated
Leaving water temperature is above 80℃