Chapter 5 - Parameter List
63
Keypad Display
Setting Range
Code
Description
LCD
7-Segment
LCD
7-Segment
Units
Factory
Default
Adj.
During
Run
Page
None
0
Int. DB-R
1
FU2-75
DB (Dynamic Braking)
Resistor Mode Selection
DB mode
75
Ext. DB-R
2
-
Int. DB-R
Yes
115
FU2-76
24
Duty of Dynamic Braking
Resistor
DB %ED
76
0 to 30 [%]
1
10 [%]
Yes
115
FU2-79
Software Version
S/W version
79
Ver x.xx
-
-
-
116
FU2-81
25
2
nd
Acceleration Time
2nd Acc time
81
0 to 6000 [sec]
0.1
5.0 [sec]
Yes
FU2-82
2
nd
Deceleration Time
2nd Dec time
82
0 to 6000 [sec]
0.1
10.0 [sec]
Yes
FU2-83
2
nd
Base Frequency
2nd BaseFreq
83
30 to FU1-20
0.01 60.00 [Hz]
No
Linear
0
Square
1
FU2-84
2
nd
V/F Pattern
2nd V/F
84
User V/F
2
-
Linear
No
FU2-85
2
nd
Forward Torque Boost
2nd F-boost
85
0 to 15 [%]
0.1
2.0 [%]
No
FU2-86
2
nd
Reverse Torque
Boost
2nd R-boost
86
0 to 15 [%]
0.1
2.0 [%]
No
FU2-87
2
nd
Stall Prevention Level
2nd Stall
87
30 to 150 [%]
1
150[%]
No
FU2-88
2
nd
Electronic Thermal
Level for 1 minute
2nd ETH 1min
88
FU2-89 to 200 [%]
1
150 [%]
Yes
FU2-89
2
nd
Electronic Thermal
Level for continuous
2nd ETH cont
89
50 to FU2-88
(Maximum 150%)
1
100 [%]
Yes
FU2-90
2
nd
Rated Motor Current
2nd R-Curr
90
1 to 200 [A]
0.1
3.6 [A]
No
116
No
0
FU2-91
Read Parameters into
Keypad from Inverter
Para. Read
91
Yes
1
-
No
No
No
0
FU2-92
Write Parameters to
Inverter from Keypad
Para. Write
92
Yes
1
-
No
No
116
No
0
All Groups
1
DRV
2
FU1
3
FU2
4
I/O
5
FU2-93
Initialize Parameters
Para. Init
93
EXT
6
-
No
No
117
FU2-94
Parameter Write
Protection
Para. Lock
94
0 to 255
1
0
Yes
117
FU2-99
Return Code
Not displayed
99
Not available
[PROG/ENT]
or
[SHIFT/ESC]
-
1
Yes
117
☞
Note:
FU2-41, 42, 43, 44, 45, 46 not displayed when FU2-39 is set to V/f or Slip compen.
24
Code FU2-76 appears only when FU2-75 is set to ‘Ext. DB-R’.
25
Code FU2-81 through FU2-90 appear only when one of I/O-12 ~ I/O-14 is set to ‘2nd function’.
Morek IT OÜ, Rauna 24, 76506 Saue Harjumaa, Estonia. www.morek.eu Tel. +372 604 1423 Fax +372 604 1447 [email protected]