Chapter 7 - Options
163
7.4 Communication option boards
7.4.1
F-Net (Needed for Communication with LG GLOFA PLC)
Open network system protocol based on IEC/ISA FieldBus
²
Specification
l
Topology: Linear Bus Topology
l
Band Method: Baseband
l
Protocol: Fnet Protocol
l
Media Access Method: Token
l
Drive link: Fiber optics
l
Number of nodes: up to 64 nodes/Bus
l
Max. Data transmission size: 256byte
l
Baud rate: 1Mbps
l
Transmission distance: 750m Max.
l
Error check: CRC-16
l
Encoding method: Menchester Biphase-L
l
Station: 0 – 63 (Setting via Keypad. Dip-switch not provided)
7.4.2
Device-Net (Field bus)
²
Features
l
Topology: Linear Bus Topology
l
Band Method: Baseband
l
Protocol: DeviceNet Protocol
l
Media Access Method: CSMA/CD-NBA
l
(Carrier Sense Multiple Access / Collision Detection – Nondestructive Bitwise Arbitration)
l
Drive link: 5-wire Cable (Twisted Pair)
l
Number of nodes: 64 nodes/Bus Max
l
Max. Data transmission size: max 8 bytes (64bits)
l
Data rates and Max. Cable length (thick): 125kbps (500m/1640ft), 250kbps (250m/820ft), 500kbps
(100m/328ft)
²
Specification
l
Device type: AC Drive
l
Communication control method:
①
Explicit Peer to Peer Messaging
②
Master/Scanner (Predefined M/S Connection)
③
I/O Slave Messaging: Polling Connection
l
Baud rate: 125kbps, 250kbps, 500kbps
l
Supply voltage: 11 - 25V
l
Faulted Node Recovery
l
Station: 0 – 63 (Setting via Keypad, Dip-switch not provided)
l
Output Assembly Instance: 20, 21(100, 101 vendor specific)
l
Input Assembly Instance: 70, 71(110, 111 vendor specific)
l
Open Style Connector
l
Interface: DPRAM
l
Supports EDS files
* Refer to communication option manuals for details.
Morek IT OÜ, Rauna 24, 76506 Saue Harjumaa, Estonia. www.morek.eu Tel. +372 604 1423 Fax +372 604 1447 [email protected]